Light steel framing design methods today rest on three things: how the building is delivered (stick-built on site, panelized or volumetric), member-by-member checks to a cold-formed steel standard, and a digital link that takes the design model straight to the roll former. The standards are being revised almost everywhere at once, and the software splits into four families. This article summarises the picture at the end of 2026, with sources, and explains what AXION changes in that chain.
Three ways to build: stick, panel and module
A light steel building (made from thin cold-formed steel sections) can be delivered in three ways:
- Stick-built: members are cut and fixed one by one on site.
- Panelized: walls, floors and trusses are made in the shop and installed on site. Panelization moves roughly 75–80% of the labour into the shop (Construction Specifier).
- Volumetric: whole rooms are finished in the factory and shipped.

The engineering gap is smaller than it looks. Designing load-bearing panels is essentially the same engineering as designing site-built framing (STRUCTURE magazine). The real difference is production data. With panels and modules, every member's length, holes, notches and assembly order has to be fixed before anything reaches the shop, and that is what the software is really expected to deliver.
Standards are changing at the same time
Every region bases light steel design on a cold-formed steel standard, and most of them changed between 2024 and 2026:
| Region | Standard | Status at the end of 2026 |
|---|---|---|
| North America | AISI S100-2024 | Published March 2025; due to be referenced in the 2027 IBC, while the 2024 codes still cite S100-16 |
| North America (framing, seismic) | AISI S240, S400 | Stewarded by SFIA since July 2024; updates target December 2026 |
| Canada | CSA S136-16 | Reaffirmed in 2021; part of the joint North American specification |
| Australia, New Zealand | AS/NZS 4600:2018 | Current; the NASH standard is used for housing |
| Europe | EN 1993-1-3:2024 | Second-generation Eurocode; first-generation Eurocodes are withdrawn on 30 March 2028 |
Sources: SDI announcement, SFIA, CSA, Standards Australia, European Commission Eurocode timeline.
Calculation methods have broadened too. The effective width method assumes only part of a thin plate carries load. The Direct Strength Method (DSM) works out member strength from the buckling behaviour of the whole cross-section. Since AISI S100-16 the two have been equal alternatives (STRUCTURE magazine).
One thing has not changed: the standards describe design largely member by member. Framing software checks members as the model is built, and whole-structure analysis is done by exporting the model to general analysis programs such as SAP2000, RFEM, RISA-3D or STAAD.Pro. In every region the engineer remains responsible for the calculation and its approval.
The situation in Türkiye: two new regulations
Until now, the seismic design rules for light steel buildings in Türkiye sat in Chapter 10 of the Turkish Building Earthquake Code, TBDY 2018 (TBDY 2018). As late as October 2025 the Turkish Constructional Steelwork Association (TUCSA) noted that there was no standard for light steel sections and connections, and that a regulation was being prepared (TUCSA). Two regulations published in 2026 have changed that.

The Light Steel Buildings Regulation
The Regulation on the Design, Calculation and Construction Principles of Light Steel Buildings was published in the Official Gazette on 17 May 2026 (issue 33256) and comes into force on 1 January 2027 (regulation text, in Turkish). It covers prefabricated, hybrid, modular and stick-built light steel buildings and applies alongside TBDY 2018. Where it is silent, Turkish (TS) standards come first, then European and finally international standards. The technical rules are in a 125-page annex (annex PDF). A few examples:
- DX51D–DX57D steels, which are meant for forming, may not be used for load-bearing studs (Section 2).
- The zinc coating must at least match the corrosion class of the building's province: 180 g/m² for low and 275 g/m² for high corrosion. The annex assigns a class to each of Türkiye's 81 provinces (Annex 1).
- A wall segment carrying lateral load must be at least 300 mm long, and its height may not exceed four times its length. Hold-downs go on the end studs of these segments (Section 6).
- Member design draws on the effective width and Direct Strength methods described above; the annex is based on AISI S100, AISI S240, AS/NZS 4600 and TS EN 1993-1-3.
The digital projects regulation
The Regulation on the Digital Preparation of Architectural and Engineering Projects was published on 5 August 2026 (issue 33331) and comes into force on 1 September 2027 (regulation text, in Turkish). It requires the 3D building model to be built on BIM (building information modelling) principles to TS EN ISO 19650, delivered as IFC (TS EN ISO 16739-1), with drawings delivered as PDF/A. Drawings must be produced from the BIM model and must agree with it.
The obligations are phased in:
- PDF/A delivery does not apply until 1 March 2029, except for buildings over 5,000 m² in the large municipalities of the largest provinces.
- IFC delivery starts in 2029, 2030 or 2031 for buildings over 10,000 m², depending on the population of the province and municipality, and on 1 September 2032 for all other buildings.
- Buildings other than residential and mixed residential-commercial buildings are exempt until 1 September 2033.
Detached buildings of no more than two storeys (not counting a basement) and no more than 200 m² of total floor area are outside the regulation's scope, as are agricultural and livestock buildings that are not integrated facilities. That exemption matters for small detached light steel houses.
Market and local software
Interest in steel and prefabricated housing grew after the earthquakes of 6 February 2023 (Milliyet, in Turkish). On 13 October 2023 the then Minister of Environment, Urbanisation and Climate Change, Mehmet Özhaseki, announced that 100,000 village houses in the earthquake zone would be built in light steel (TRT Haber, in Turkish). Steel's share is still small, though: TUCSA's October 2025 review puts it at about 2.4% of construction in the earthquake zone and 0.4% of housing.
In Türkiye, light steel software has mostly grown up as part of a machine maker's chain. Arkitech's design software takes DXF and IFC files as an underlay, checks capacity to AISI and Eurocode, exports the model to SAP2000 and outputs to Arkitech machines (Arkitech). In Özok Steel's TeoCAD/TeoCAM chain, stud layout, panel splitting and bracing are derived from the architectural plan, and after analysis the model goes to Teotech machines (Özok Steel). Foreign makers are paying attention too; FRAMECAD exhibited at Turkeybuild 2024 (FRAMECAD).
A BIM workshop report published by the Ministry of Environment, Urbanisation and Climate Change in May 2025 notes that small firms struggle with software and training costs. It sees dependence on software licences as a threat and the development of local software as an opportunity (workshop report, in Turkish).
The software landscape: four families
Light steel software falls into four families, each with its own strength and its own point to watch:

| Family | Examples | Strength | Point to watch |
|---|---|---|---|
| Machine maker's software | FRAMECAD Steelwise, Scottsdale ScotSteel, BlueScope ENDUROCADD | Seamless flow from design to machine | Usually built around the maker's own machines |
| CAD/BIM add-in | StrucSoft Metal and AGACAD Metal Framing (Revit), Tekla Framing Tools | Same environment as the architectural BIM model | Needs a licence for, and skills in, the host program |
| Standalone framing and design tool | Vertex BD, SteelSmart System, Simpson CFS Designer | Independent of a host program | Scope varies widely between products |
| General structural analysis | SAP2000, RFEM, RISA-3D, STAAD.Pro, SkyCiv | Analysis of the whole structure | Produces no fabrication data (holes, notches, assembly order) |
Sources: FRAMECAD, Scottsdale, StrucSoft, Tekla, Vertex, Dlubal.
Two trends sit side by side on the machine side. Vertically integrated chains tie the design software to the maker's own roll formers. At the same time the market is opening up: Howick machines read an open CSV format, FRAMECAD's cloud platform Nexa accepts files from other design software, and the Revit add-ins export to many machine brands.
2024–2026: cloud, automation and AI
Most recent innovation has happened on the production side:
- Cloud production platforms: FRAMECAD Nexa launched in October 2024 (engineering.com) and Scottsdale ScotFab in September 2026.
- Robotic assembly: besides roll formers working from the digital model, robot arms now assemble panels and laser scanners check tolerances (SFIA).
- Free online calculators: makers offer single-member checkers, and they state themselves that these do not replace engineering verification.
- AI: browser-based beta tools that read a file produced by an AI assistant, and rule-based tools that convert timber-frame plans to steel, have appeared. This research found no verified product in which AI performs a code-compliant design and approves it on its own.
The cost of working across separate programs
In many firms the work still moves along a chain: the plan is drawn in CAD, framing is built in another program, quantities go into a spreadsheet, the quote into a word processor and the machine file into the maker's software. Every hand-off means retyping data, and every retype is a new chance for error. Vendors say so too: both FRAMECAD and StrucSoft present their products as an answer to export-import errors and manual re-entry.

With a single model every output comes from the same data. Move a window and the framing, cladding, quantities, quote, sheets and machine file all change with it; nobody types the same information twice.
What AXION brings
AXION is a standalone Windows program that takes a light steel building from plan to roll former in one model. It does not need Revit or AutoCAD. These are the main innovations:
From plan to model, one set of data
A DXF or DWG plan opens as an underlay and the walls are built from it (DXF underlay and model from plan). Existing .axd and .tcf light steel files can also be imported as framed panels. Framing follows rules and keeps your manual edits. Roofs and trusses, cladding (Betopan, plasterboard, OSB, insulation, trapezoidal sheet), rooms, quantities and quotes all come from the same model.
Production without brand lock-in
AXION writes four machine formats: ARK (.ark), Howick CSV, TeoCAD AFF and BADE CAD BDE. Tools, gaps and speeds are set per machine (Machine settings), so the same model can go to roll formers from different makers. Our article on light steel machine files covers the details.

Checks before production
CHECK › Run All Checks runs Model Health, Joint Check, Cladding Clash, Production Validation and Cladding Validation in one go. Profile Check highlights members that run into each other, and members whose length falls outside the machine's limits, in the 3D model (Checks). Errors are found on screen, not in the workshop.
Documents for the shop and the site
Numbering, QR codes on panels, work orders, sheets and the quote PDF come out together from the Output centre. Sheets, lists, work orders and quotes can be written as PDF/A-3b for long-term archiving; PDF/A is also the format named in Türkiye's digital projects regulation. Because every sheet is drawn from the same model, drawings and model do not drift apart.
A common language with engineers and BIM teams
AXION does not perform structural calculations; it deliberately leaves them to the engineer. Instead it hands over the member model ready for analysis: Analysis model (SAP2000 .s2k) and Analysis model (IFC4 structural) are in every package, and the engineer runs the calculation in their own program. CHECK › Regulation › Place Anchors puts hold-downs on both end studs of every lateral-load wall segment at least 300 mm long, as Türkiye's Light Steel Buildings Regulation requires; the engineer's calculation confirms each anchor's capacity. Projects export as IFC 4.3, the current edition of the international standard ISO 16739-1:2024 (ISO). Türkiye's digital projects regulation cites the same standard as TS EN ISO 16739-1; check with the approving authority which IFC version it expects. See BIM delivery with IFC for more.
AI assistant: modelling by instruction
AXION connects to AI tools such as Claude and ChatGPT through MCP (Model Context Protocol, an open way for an AI tool to use a program safely). A request such as "Add a roof level at 6200 mm" is turned by the AI tool into one of AXION's own commands.

The connection only works on the same computer and the same Windows account. Every change the AI makes is a single Undo step. It asks before changing or deleting an existing library record, and it never makes up prices or machine codes. The feature comes with the "MCP AI Connection and Company Libraries" module (AI assistant).
What AXION does not do
- It does not provide the structural calculation or regulatory approval; it builds the analysis model, and the calculation and signature stay with the engineer.
- It writes the four machine formats listed above; a machine outside that list needs its format supported first.
- The AI assistant does not decide for you; you see everything it does and can undo anything you don't like.
Frequently asked questions
Which standard is used for light steel framing design?
It depends on the region: AISI S100 in North America, EN 1993-1-3 in Europe and AS/NZS 4600 in Australia and New Zealand. In Türkiye the Light Steel Buildings Regulation applies from 1 January 2027, together with the TBDY 2018 earthquake code.
Is designing panels different from designing stick-built framing?
The structural design is essentially the same. The difference is production data: with panels, every member's length, holes and assembly order are fixed before the shop starts.
Does framing software do the structural analysis too?
Some tools check members one by one; whole-structure analysis is usually done in programs such as SAP2000 or RFEM. AXION does not calculate, but it hands those programs a ready analysis model.
What is AI good for in light steel design today?
Mainly speeding up repetitive modelling. There is no verified product that does the calculation and approval in place of the engineer.
Which roll formers does AXION work with?
It writes ARK (.ark), Howick CSV, TeoCAD AFF and BADE CAD BDE files, with tools, gaps and speeds set per machine.
Conclusion
Light steel design methods are mature and the standards are being renewed; in Türkiye two new regulations, one for light steel buildings and one for digital projects, come into force in 2027. The real change, though, is in the data chain from design to production. AXION brings that chain into one model: plan, framing, quantities, quote, machine file, sheets, analysis model and IFC all come from the same data. Our guide to choosing light steel framing software explains what to look for, and you can try AXION on your own project with a 7-day trial.
Product and company names in this article (ArkitechDesigner, Howick, TeoCAD, BADE CAD, FRAMECAD, Scottsdale and others) are trademarks of their respective owners. AXIONBIM is not affiliated with these companies and supports the ARK, Howick, TeoCAD and BADE CAD file formats for interoperability only.
Published: · Updated:
Try it on your own project
Create an AXIONBIM account, download the program and try it free for 7 days from your first login. No card details required.
Other articles
- Light gauge steel house vs container home: how they compare
- Light gauge steel fire resistance: how steel stud walls get rated
- Light gauge steel construction process: 10 stages explained
- Soundproofing steel stud walls: layers, decoupling and sealing
- Light gauge steel vs structural steel: key differences explained
- Exterior cladding for light gauge steel houses: options and details