Guide topics

32

Checks

The CHECK tab checks the model before it is sent to production: disconnected joints, clashing profiles or profiles the machine cannot produce, walls that run into each other at a corner, trapezoid cuts that do not sit on a bend, and overlapping boards. The buttons other than Fix Corners do not change the model.

Run All Checks

CHECK › Model › Run All Checks runs Model Health, Joint Check, Cladding Clash, Production Validation and Cladding Validation at once and shows the result in a single list. Start the check from here.

  • The boxes at the top filter the list by a single check (the row count in brackets) and by importance (Errors only, Warnings only, Info only); the search box searches category, code, description or element name.
  • Double-clicking a row selects the element (two elements in a clash) and the screen zooms there. Select and Edit selects the element; the window stays open.
  • Open in Check opens the row's own check; the fix buttons are there. Refresh runs the checks again.
  • The same problem is not counted twice: for example a profile clash appears only as a Production Validation row and selects the two profiles together.

Model Health

CHECK › Model › Model Health checks the whole model in a single list: missing identity, name, mark, level and material; invalid geometry, section and local coordinate system; BIM information; profiles that overlap in the frame or run into each other between two panels; the joint between two panels placed end to end running through a door or window (the opening is split between two panels, so the header and sill are not one piece); a brace that crosses the panel edge into the next panel. The last two are warnings; the program does not fix them, you move the opening or the panel yourself.

  • Each record has a Severity (Error, Warning, Info), a Category, a Member, a Code and a Description. At the top it says how many errors, warnings and information items there are.
  • The Topic box filters the list to one topic (for example Framing or Other (identity, geometry, level, BIM)); the box next to it filters by importance, and the search box searches the text.
  • Double-clicking a row selects the element and the screen zooms. Select and Edit selects the element in the main scene; while the window is open you can edit its properties in the panel on the right.
  • Safe Fix applies the automatic fix of the selected record: gives a missing name or mark, changes a repeated mark, and links an element with no level to that level if there is a single level in the project. At the bottom it says what the fix will do; for a record with no automatic fix it says "This entry will not be changed automatically".
  • All Safe Fixes applies all safe fixes in a single undo step.

Joint Check

CHECK › Framing › Joint Check is an on / off button. When on, a mark is drawn at every profile end in the 3D model:

  • Green ring: the end sits on the other profile and the screw holes of the two profiles are at the same point; the connection is made. The label shows the screw count and the profile it is connected to.
  • Red cross: the end sits on no profile; it is free.
  • Red square: the end sits on a joint but no fastener (screw) could be produced.
  • Dashed red square: there is a screw but the holes of the two profiles do not coincide; a single screw does not hold two sheets together. It mostly shows that the end does not overlap the flange of the other profile (there is no lip extension).
  • Orange line and two short ticks: the difference between the design node (the point where profile axes intersect) and the real production end of the profile. On a shortened end the label says Cut allowance (sheet thickness + the assembly gap per end of the active machine, for example 3.2 mm), and on an end whose lip is extended it says Extension.

What is checked:

  • The selected panels (or the panel of the selected profiles) are checked; if nothing is selected, all visible panels. If a panel is selected, all its ends are labelled; with no selection, labels are written only on problem ends.
  • When you click the button, the status bar says how many ends are connected, free, without screw or with a hole that does not match.
  • Problem ends, profile clashes and the warnings of panel joints (a free end of a panel, a corner angle other than 90° and 135°) are written to the Problems panel on the right. The eave end of a gable wall built by Create roof is not counted as free; the roof trims cover that end.
  • The check does not make its own calculation: joints and screws are read from the fabrication data that the production file uses. An end that looks red in the model is also unconnected in the production file.

Profile Check

CHECK › Framing › Profile Check is an on / off button. When on, profiles that will cause problems in production are marked in the 3D model:

  • Red frame: two profiles are inside each other. Overlapped in the same panel (for example a stud produced twice in the same place), a perpendicular profile pierces a web with no notch (a notch is a cut opened where the profile will pass), or the profiles of two different panels are inside each other (at a corner, in panels drawn on top of each other). A frame is drawn around both profiles and the label shows the interpenetration length ("Clash 40 mm"). Normal joints (an end entering a mouth, a lip overlap, a continuous flange with a notch, back-to-back contact) and contact up to 0.5 mm are not counted as a clash.
  • Purple frame: the production length of the profile is outside the limit of the active machine ("Short 80 mm < 100 mm", "Long 12400 mm > 12000 mm"). The limit is the Min / Max values of the Profile length (mm) of the machine (see the "Machine Settings" topic). Flat strips are not in the length check because they are not produced on the machine. If there is no active machine, the length is not checked; the status bar says so.

What is checked is the same as in Joint Check: the selected panels, or all visible panels if nothing is selected.

  • The status bar says how many clashes, short and long profiles were found; the problems fall into the Problems panel. Clicking a clash row selects the two profiles together and brings them to the screen.
  • The marks refresh as the model changes.
  • No automatic splice is made for a long profile; splitting the profile or making the panel smaller is up to you.

Fix Corners

It corrects walls that run into each other at corners: the panel running through the corner extends to the outer face of the other, the butting panel starts at its web face; an end that finishes inside another wall is pulled to the face of that wall.

  1. To correct only certain corners, select two or more walls. If nothing is selected, all walls in the project are considered.
  2. Click Fix Corners. If there is no corner to fix or a panel cannot be fixed, a message appears.
  • Doors and windows stay where they are; a corner that is already correct is not touched.
  • Only vertical, rectangular walls are considered; trusses and roof panels are not included.
  • Walls you draw now join at corners automatically with this rule. The button is for walls drawn earlier; saved projects are not changed automatically when they are opened.

Rib Cut Check

A rib is each wave of the trapezoidal sheet. Trapezoidal sheet cannot be cut anywhere: if a door or window cut does not sit on a bend, the edge is left free, the casing or Omega does not rest on the web of the sheet and it takes water. CHECK › Cladding › Rib Cut Check catches these cuts before production.

  • The selected panels are checked; if nothing is selected, all panels in the project.
  • The result is written in a message box; every cut that does not sit on a bend also falls into the Problems panel, and clicking the row goes to the panel.
  • The rule is the same as in Cladding Validation and in the Cladding panel. Only layers whose layout is Opening-aware (rib grid) are checked; layers with a Sequential (from panel start) layout are listed as "not checked" (see the "Cladding" topic).

Cladding Clash

CHECK › Cladding › Cladding Clash checks whether the boards of two panels cover the same place; the clashing place is where the board boundary should be. The outer and inner cladding of the visible wall panels is checked. The window has two tabs:

  • Clashes: Panel, Clashing panel, Face, Overlap and Description. Double-clicking a row selects the two panels and the screen zooms.
  • Board boundaries: where the board ends at corner and T joints: the rule, the outer and inner board length per panel and the allowance at the two ends.

The boundary is resolved by which panel runs through in front, according to the corner cladding rule (PROJECT › Project Info › Project Settings › Corner cladding). After you change the model, click Refresh.

Problems panel

The rows found by Joint Check, Profile Check, Rib Cut Check and 3D MODEL › Interfere are listed in the Problems panel on the right-hand strip.

  • The badge on its button shows how many problems there are.
  • The panel opens automatically when you start a check and when a problem is found. A check that runs automatically when the frame is refreshed does not open the panel; it only updates the badge.
  • Clicking a row takes the model to that profile or panel; a clash row selects two profiles or two layers together.