The main light gauge steel profile types are the C stud and the U track. C-shaped members with stiffening lips carry load as wall studs, floor joists and roof truss chords, while U-shaped tracks without lips cap the top and bottom of a wall and hold the stud ends. Builders also use hat (omega) sections, Z sections, angles and flat strap. All of them are roll formed cold from galvanized sheet steel and are identified by shape, web depth, flange width and thickness.
This guide covers what each profile does, how to read size designations such as 600S162-54, how structural studs differ from drywall studs, and what decides the section on a real project.
What is a light gauge steel profile?
A light gauge steel profile, also called a cold-formed steel (CFS) member, is made by bending thin galvanized coil into shape at room temperature. Hot-rolled sections such as I-beams are much thicker. Cold-formed members are thin enough to be produced on a roll forming machine and cut to any length.
Many framers now produce members per project. The machine uncoils the strip, forms the section, punches service holes and connection points, and cuts each part to length with its part number printed on it. So the member list in a light steel project is also production data. We describe the file formats those machines read in production files for light steel roll formers.
The zinc coating protects the frame from corrosion. How the coating class affects service life is covered in light gauge steel house lifespan.
C studs and joists
A C section has a web, two flanges and a lip at the end of each flange that turns inward. The lip stiffens the thin flange against local buckling, which raises the capacity of the member. Most load-bearing parts of a light steel building use this lipped C shape.
Typical uses of C sections:
- Vertical studs in wall panels
- Floor joists and ceiling joists
- Top and bottom chords and web members of roof trusses
- Headers, jambs and sills around door and window openings
One web depth can come in several thicknesses. The studs in a wall and the joists above it may share a section family and still differ in thickness. The structural design decides which thickness each member needs.
U tracks
A track has no lips. Its web is just wide enough for the stud to slide in, so the studs sit inside the track. The bottom track and top track of every wall panel are U sections.
Tracks also show up as:
- Rim track closing the ends of floor joists
- Horizontal members above and below openings
- Box sections, made by nesting a C stud inside a track
The bottom track is anchored to the foundation or slab. That connection is covered in light gauge steel house foundation.
Hat, Z, angle and strap sections
A hat section (also called an omega or furring channel) is used as a cladding batten on walls, as a roof purlin under sheet roofing, or as a ceiling furring member. Because it holds the cladding off the frame, it is common in ventilated facade details.
Z sections are used mainly as roof and wall purlins, and their shape lets them lap over each other at supports to form a continuous line.
Angles serve as clips, edge trim and reinforcement. Flat strap works as diagonal bracing in the plane of a wall or floor and limits racking under lateral loads. Strap braces are usually screwed to the corner studs and tracks of the panel.
How to read light gauge steel sizes
Four values identify a profile: shape, web depth, flange width and thickness. For lipped sections, the lip length is listed in the section table too.
In North America the SSMA designation is common. Take 600S162-54:
| Part | Meaning | Example |
|---|---|---|
| 600 | Web depth in 1/100 inch | 6.00 in |
| S | Member type (S: lipped C stud or joist, T: track, U: unlipped channel, F: hat/furring) | Lipped C stud |
| 162 | Flange width in 1/100 inch | 1.62 in (1-5/8 in) |
| 54 | Base steel thickness in mils (1/1000 inch) | 54 mil |
A 362S162-43, by the same logic, is a 3-5/8 inch C stud with a 1-5/8 inch flange and 43 mil steel. Common web depths for studs include 3-5/8, 6 and 8 inches.
Older documents and store shelves still use gauge. Gauge runs backwards: a higher number means thinner steel. Published gauge to mil conversions vary slightly between sources (one manufacturer lists 54 mil as 16 gauge), so design and ordering should use the mil value from the manufacturer's data.
Outside North America, sizes are usually given in millimeters as web x flange x lip x thickness. Naming differs between suppliers, so check the section table in the catalog before you order.
Structural studs vs drywall studs
Steel studs for drywall partitions look a lot like structural light gauge steel. Both are galvanized C and U sections. They are not interchangeable.
| Structural light gauge steel | Drywall (non-structural) studs | |
|---|---|---|
| Job | Carries building loads to the foundation | Holds gypsum board in partitions and ceilings |
| Thickness | Heavier, chosen by structural design | Thinner |
| Where used | Exterior walls, floors, roofs | Interior partitions, linings, ceilings |
| Design | Engineered | Follows the board system manufacturer's details |
Thin interior studs are used for light non-load-bearing partitions; heavier gauges are reserved for load-bearing walls. If a quote for a steel frame house does not list member thickness and steel grade, ask for them.
What determines the profile you need?
The section and thickness come from structural calculations for the specific building. The main inputs are:
- Span and spacing. Longer joist spans or wider stud spacing need deeper or thicker sections.
- Loads. Number of stories, floor live load, snow, wind and seismic demand all change the section.
- Wall height. Taller studs are more prone to buckling.
- Openings. Headers over doors and windows often need doubled members or box sections.
- Insulation. Web depth also sets the cavity depth available for insulation.
- Machine tooling. A roll former can only make the sections its tooling allows, so the design has to match what the machine produces.
In the US, cold-formed steel framing is designed to AISI standards, and lateral systems such as shear walls and strap bracing are a separate design topic. In Turkey, a dedicated light steel building regulation was published in May 2026 and takes effect on 1 January 2027. Wherever you build, member sizing belongs to a structural engineer working to the local code.
Turning profiles into a member list
Once sections are chosen, every wall, floor and roof panel gets a parts list with section, length, holes, part number and assembly order. Doing this by hand gets error prone on buildings with many openings. When quantities, cut lists and machine files all come from the same list, they stay consistent. We cover that in taking light steel quantities from the model.
AXION builds wall, floor and roof panels from a company's own framing rules, places jambs, headers and sills around openings, and pre-checks members against the roll former's tooling before writing the machine file. See the features page for details.
FAQ
What are the main types of light gauge steel profiles?
Lipped C sections for studs, joists and truss members; U tracks at the top and bottom of walls; hat (omega) and Z sections for purlins and cladding battens; angles for clips and trim; and flat strap for bracing.
What is the difference between a C stud and a U track?
A C stud has inward lips on its flanges and carries load. A U track has no lips and receives the ends of the studs at the top and bottom of a wall.
What does 600S162-54 mean?
It is an SSMA designation: 6 inch web, S member type (lipped C stud), 1-5/8 inch flange, 54 mil thickness.
Can drywall studs be used for structural framing?
No. Drywall studs are thinner and made to hold gypsum board in partitions and ceilings. Load-bearing walls need structural studs sized by an engineer.
Is a lower gauge number thicker?
Yes. Gauge is inverse, so 16 gauge is thicker than 20 gauge. Use the mil thickness from the manufacturer's data rather than gauge when you design or order.
Summary
Most of a light steel frame is lipped C studs and joists set into U tracks and braced with strap, with hat, Z and angle sections used for cladding, purlins and connections. A member is fully defined by its shape, web depth, flange width and thickness, and the structural design for the building sets all four.
Published:
Try it on your own project
Create an AXIONBIM account, download the program and try it free for 7 days from your first login. No card details required.
Other articles
- Light gauge steel house vs container home: how they compare
- Light gauge steel fire resistance: how steel stud walls get rated
- Light Steel Framing Design Methods and Software in 2026
- Light gauge steel construction process: 10 stages explained
- Soundproofing steel stud walls: layers, decoupling and sealing
- Light gauge steel vs structural steel: key differences explained
- All articles