27
Cladding
Cladding is the set of layers fitted to both faces of a panel and inside the frame: Betopan, plasterboard, OSB, insulation, water/vapour barrier, tape and trapezoidal (ribbed) sheet. You choose the layers in the Cladding panel on the right; the program places the boards automatically according to the panel boundary, doors and windows. The 3D model, the cutting list, the cutting plan and the cladding work order all use the same layout.
Opening the Cladding panel
- On the right-hand strip, click the Cladding icon directly below Properties.
- With cladding switched on in 3D, Alt + click a board: the Cladding panel opens with the row of that panel, that face and that material selected.
- In the Project Explorer, click the cladding layer row of a panel: the panel opens with that layer.
- To see the cladding on screen, switch on the VIEW › Model Display › Cladding button (see the "View and Display" topic).
The box at the top of the panel tells you what you are editing:
- When a panel is selected: changes wait as a draft; Apply at the bottom of the panel writes them to the selected panels. This button does the same job as Apply in Properties; changes made in both panels are written together. If several panels are selected, the same layer stack is copied to all of them.
- When no panel is selected: you edit the default cladding of panels you draw from now on (the new-panel recipe). The change is saved immediately; Apply is disabled.
Step by step: adding a layer to a panel
- Select the panel and open the Cladding panel.
- In the Face and layers section, choose the face: Face A (outer face), Core · in-frame / flange (insulation in the frame cavity and the tape that goes on the profile flange) or Face B (inner face).
- Choose a material from the list below and click Add. The list contains the cladding materials of the Material and Section Library.
- Change the order of the layer with ↑ and ↓; remove a layer you do not want with Delete.
- Click Apply.
Columns and buttons of the layer table:
- Material: the name of the layer.
- Thk.: thickness (mm).
- Cut: a board that is ticked goes into the cutting plan. Insulation, barrier and tape are not cut even if ticked.
- Direction: Panel, Vertical or Horizontal. A layer with direction "Panel" follows the Default direction below.
- Colour: the colour of the layer on screen (#RRGGBB code). If you leave it empty, the colour of the material is used. For a ready-made colour, choose it from the list below and click the Colour button; type a colour that is not in the list as a code in the box next to it.
- Clear face: deletes all layers of the visible face.
- A ↔ B: swaps the layers of faces A and B.
Below the table you see the number of layers and the total panel thickness, and below that the quantities of the selected panels (net and gross surface, profile length, weight) and the number of layers to be cut.
Cladding systems
A cladding system is a ready-made layer stack with a name (for example "Dış duvar", "İç bölme", "Islak hacim", "D-03 · Trapez cephe (19/1000 D)"). The list depends on whether the panel is an exterior or an interior panel.
- Load: brings the layers of the system selected in the list. If edge margins and a board direction are saved in the system, it brings those too; if they are not saved, it leaves the values on screen unchanged. With a panel selected, click Apply afterwards; with no panel selected, the system immediately becomes the new-panel default.
- Save: type a name in the box below and click. The layers of the three faces, the edge margins of the two faces and the board direction are stored under this name. If you type an existing name, that system is updated.
- Delete: removes the selected system from the list. The cladding of panels does not change; only the link to the system is cut. Systems that come with the program can be deleted too; if you save again under the same name, it comes back.
The line under the system box tells you the state of the panel: linked to a system, derived from a system (details changed on the panel) or "Custom cladding" (not linked to any system).
The ready-made D-03 · Trapez cephe (19/1000 D) system brings Trapezoid 19/1000 D on the outer face, 3x40 insulation tape on the profiles and 80 mm rock wool; the edge margins are 10 bottom, 5 top, 0 side (mm). The inner face is empty: you can add the inner board yourself and save the system under your own name.
Sheet size, joints and edge margins
The Sheet and layout section edits the layer selected in the table; the box above the fields tells you which layer it is.
- Sheet width × length: the size of the board (mm).
- Joint V / H (mm): the open vertical and horizontal joint left between boards.
- The values come from the material library. If you change them here, they apply only to this panel and are kept even when the library is updated.
- For layers that are not cut (insulation, barrier, tape) these boxes are disabled. Trapezoidal sheet has no joint; the overlap comes from the section of the material.
- If you change the joint of a material in the Material and Section Library and click Save changes, all panels using that material are updated; sizes and joints entered specially on a panel are kept.
The settings under Panel-wide are for all layers:
- Default direction: Vertical or Horizontal. It affects only layers whose direction is "Panel".
- Edge margins (mm): separately for Face A and Face B: bottom, top and side. This is how far inside the panel edge the board ends.
Board layout (flat boards)
The program lays boards by these rules:
- Boards are laid from the start of the panel. If there is a door or window, the wall piece next to it starts from the edge of the opening: the full board goes next to the opening, the cut piece goes to the end of the panel.
- Pieces next to an opening end at zero on the opening edge and are full length. The piece under a window, the piece over a window and the piece over a door are separate pieces; they sit at zero on the sill and the head and are narrower by one joint on both sides.
- If the strip under a window, over a window or over a door fits the sheet as it is or turned a quarter turn, it comes out as one piece (for example a 2000 × 900 door-head strip on a 1250 × 2500 sheet). If Allow 90° rotation in the cutting layout is off for the material, the strip is not turned and is split instead. A strip that fits in neither direction is split into pieces of equal width (a 3000 mm strip on a 1250 sheet becomes three pieces of 1000 mm).
- On a panel with sloped edges or a polygon, boards are laid in the outer rectangle and the part outside the panel is cut off; the piece on a sloped edge ends at the same angle.
- If the board size and joint of the two faces are the same, the boards of Face B are laid on the grid of Face A; the joints face each other. If the sizes differ, each face is laid from its own edge margin.
There are two more layout settings chosen in the material (the Joint and edge tab, below):
- Board layout › From the centre: on a panel without doors and windows, boards are spread symmetrically from the centre to both sides, and the cut pieces at the two ends are the same size. The program chooses the layout with less waste; if an end piece would be narrower than the Narrowest end piece value (default 150 mm), it takes the other layout. Example: 1250 mm Betopan, 16 mm joint, 2044 mm panel: 381 · 1250 · 381. With a centre layout the joint may not fall on a stud; use it for a material whose joint takes an H or OMEGA profile, and leave plasterboard, whose joint must fall on a stud, on From the edge.
- End joints: Aligned (the short-edge joints are on the same line in every row) or Staggered (half sheet) (like brickwork, every second row is shifted by half a sheet). On floors and roofs OSB is mostly laid staggered.
With cladding and Panel names on, a faint text in the middle of each board in 3D shows the face ("Face A" / "Face B") and the size (for example 1250x2500).
Board edges and corners
The Edge behaviour of the material decides how the board ends at the panel end:
- Stop at panel boundary (the default for flat boards): the cladding ends at the panel boundary and no extension beyond the panel end is used. The shortening at a corner is always applied; the board overhangs at a corner only if Option 1 below is chosen.
- May cover the frame and May wrap the free end: the cladding may go beyond the panel boundary; the extension allowance defined for the panel end is kept.
- Needs a finishing profile (trapezoidal sheet): the cladding ends at the panel boundary; at a corner it neither overhangs nor shortens.
Where the board ends at corners and T joints is shown by the Board boundaries tab of the CHECK › Cladding › Cladding Clash window (see the "Checks" topic).
Cladding at a corner. At a square wall corner one of the panels runs through the corner (its frame goes to the outer face of the other panel) and the other butts against it. Board ends are cut automatically accordingly, and the side edge margin is not applied at the corner end:
- Inside corner side (the face between the two panels): the board of the running panel ends at the frame of the butting panel; the board of the butting panel starts 3 mm from the board of the running panel with a joint. The board does not enter the frame of the neighbouring panel.
- Outside corner side (the projecting face of the corner): the board of the running panel ends at the end of its own frame, and the web end is left open. Choose how it is closed in the Corner cladding tab of the PROJECT › Project Info › Project Settings window.
Outside corner options:
- Option 1 · The butting panel's board covers the corner (default): the outer board of the butting panel overhangs beyond its frame (90 mm web, 10 mm board: 100 mm). There is no extra piece; the overhanging board must be protected in transport.
- Option 2 · Corner strip (fitted on site): both boards end at their own frame; the strip between them is cut separately from the same board. The strip is a separate page in the cladding work order and a separate line in the cutting plan and the material list; on site it is screwed to the corner stud of the running panel.
- Option 3 · L corner trim: both boards end at their own frame and an L sheet covers the open part. You enter the two leg lengths, the sheet thickness and the material / stock code in the same tab; this option cannot be chosen until the sizes are entered. The sheet is visible in the 3D model and counted in the material list in metres and pieces.
If you want a different option for a single corner, select the panel and change the corner at the start or end of the panel in Properties › Sheet › Corner cladding. The first option is the project setting; the choice is written to both panels of the corner together.
Joint profile (OMEGA, PVC H)
A joint profile is the profile placed in the joint between boards (for example OMEGA behind the joint, PVC H inside the joint). It can change from project to project or from board to board, so it is chosen on the board itself:
- Select the panel and, in the Cladding panel, select the board in the layer table.
- In the Sheet and layout section, choose from the Joint profile list: As in the library (uses the rule in Material and Section › Cladding consumables; if there is a rule, its product is shown in brackets), None (no profile is placed even if the library has a rule) or an accessory / tape product from the library.
- Choose the Joint direction: vertical and horizontal, vertical only or horizontal only joints.
- Click Apply.
- The choice applies only to that board: you can give OMEGA to BETOPAN 10mm on the outer face and PVC H to BETOPAN 8mm on the inner face.
- With no panel selected, the choice is written to the new-panel default. If you save it in a cladding system, panels using that system get it too.
- The option is visible only on a flat board that is cut; trapezoidal sheet has no joint.
- In the cladding work order (PDF and DXF) the profile is drawn over the joints only on the page of that board and written with a length list; in the material list and the quote it is counted in stock lengths.
- If the list has no product, first define the joint profile on the Material and Section › Cladding materials page with type Accessory and its length in the Stock sizes tab (see the "Cladding Consumables" topic).
Trapezoidal (ribbed) sheet
A rib is the repeating wave of the trapezoidal sheet (crest and valley). When you select the trapezoid layer in the table, the Ribbed sheet section opens in the panel:
- Sheet face: turns the face of the sheet that can be seen from outside (crowns outside or wide face outside). The face given to new panels is the Visible face setting of the material.
- Extra overlap: switches on or off one extra rib of overlap at a single sheet joint; the other joints stay standard.
- + Sheet / − Sheet: adds one sheet to the automatically calculated number; removes the last sheet added by hand. The text between them is the number of sheets.
- Edge closure allowance (mm): a small gap left at the end of the panel up to this value is covered by the edge closure profile; no separate sheet is created.
How the trapezoid is laid is the Trapezoidal layout setting of the material:
- Sequential (from panel start): the first sheet starts at the panel start, the next ones advance by the effective width, and the last sheet is cut at the panel end. You can shift the joints (see "Editing sheets by hand" below).
- Opening-aware (rib grid): the ribs sit on both edges of the panel, the joints are on a rib, and neighbouring sheets overlap by one rib. Doors and windows are taken inside a full sheet; the narrow piece cut lengthwise (on Trapezoid 19/1000 D: 2 ribs 358, 3 ribs 527, 4 ribs 696, 5 ribs 865 mm) goes to the region without doors and windows. The program tries the possible layouts and chooses the one that needs the fewest sheets to be ordered. The layout is calculated from the panel every time: when you move a window or lengthen the panel, the layout refreshes automatically.
With the opening-aware layout:
- If one rib remains open, no narrow piece is cut; one sheet is overlapped by one extra rib. If Do not rip strips (overlap full sheets) is ticked in the material, no lengthwise cut is made at all; the missing ribs are closed by overlapping full sheets more. The extra overlap is always at a single joint.
- Whether the panel is closed with full sheets or with one narrow piece is written at the top of the Cladding panel (for example "Closing: 2 full sheets, 1 narrow piece(s) (527 mm)."). If it does not close with full sheets, it also says how much the panel must be shortened or lengthened to close: on Trapezoid 19/1000 D the widths that close exactly are 1029, 2043, 3057 mm…, so for a 2550 mm panel a 507 mm shortening (2 sheets) or a 507 mm lengthening (3 sheets) is suggested.
- If the panel length does not match a whole number of ribs, the last sheet is cut through the middle of a rib; the line says "The panel edge is not on a rib" and gives the two nearest suitable widths. The line is orange in this case.
- The same information appears in the cladding work order and in Cladding Validation (see the "Production Readiness" topic).
The ready-made Trapez 19/1000 D material comes with 1040 mm sheet, 169 mm rib pitch, 19 mm height and 1014 mm effective width; the wide face is outside and it is laid opening-aware.
Door and window cut (rib rule)
Trapezoidal sheet cannot be cut anywhere: the cut next to a door or window must sit on a bend of the rib (the crest edge or the valley bend). On opening-aware trapezoid:
- At a window the bend may pass the casing web by at most 3 mm or stay 17.25 mm short; at a door there is a ±12 mm allowance under the Omega. If there is no bend in this allowance, the sheet is cut straight.
- If the cut does not sit on a bend, the line at the top of the Cladding panel says which edge it is and by how much the edge or the door/window must be moved to sit (for example "Window: both edges fit if shifted 45 mm to the left or 62 mm to the right."). The edges between twin windows are not counted.
- On a sheet whose wide face is outside, such as Trapezoid 19/1000 D, the flange on the trapezoid side of the window side casing and of the door Omega sits in the middle of the nearest flat; the casing top and the Omega leg are calculated separately for each side, and no warning appears for an edge that sits like this. The two sides can have different sizes.
- To check all trapezoid cuts of the project, use CHECK › Cladding › Rib Cut Check (see the "Checks" topic).
Casing and Omega at door and window edges
On opening-aware trapezoid the edge of a door and a window is closed with bent sheet parts; the trapezoid ends under these parts:
- Window: a hat-shaped side casing on both sides, a Z-shaped sill at the bottom and a head at the top. The trapezoid ends in the web of the hat at the sides, 18 mm below the sill level at the bottom and 17 mm above the head level at the top.
- Door: an Omega on both sides. The trapezoid ends 84 mm back from the net edge (under the Omega) and 15 mm above the door level at the top.
- Twin window: if the distance between two side-by-side windows is 387 mm or less and their bottom and top levels are the same, the trapezoid between them is not cut; a middle casing of that width is fitted between them, and the sill and head cover both windows in one piece.
- If the whole width of a sheet falls in this closing band, the sheet is split into a lower and an upper part. A sheet that falls only partly in the band stays full length and is notched (in the cutting list, for example "notch 164×2165"). If the overlap edge goes beyond the band by less than 30 mm, it is not notched; the casing covers it.
- Casing and Omega are drawn green in the 3D model. A window set (side casings, sill, head) becomes one welded frame in the workshop; the door Omegas stay separate parts. Fabrication sheets and flat patterns are in the Output centre (see the "Output Centre" topic).
- The common sizes of the door Omega are in the Properties › Doors and windows table of the panel (see the "Doors and Windows" topic).
The sheet thicknesses are in the trapezoid material: in Material and Section › Cladding materials › Joint and edge tab, Casing sheet, Sill sheet, Head sheet and Door Omega sheet (mm). An empty box is the default: casing 0.75 · sill 1.25 · head 0.75 · Omega 1 mm; the value must be 0.3–3 mm. When the thickness changes, the outside sizes stay the same; the inner faces and the flat pattern change with the thickness.
Window casing sizes of the panel. The outside sizes of all windows on a panel are changed in the Cladding panel:
- Select the panel and select the trapezoid layer in the Cladding panel.
- In the Ribbed sheet section, type the values in the Window casing (this panel only) boxes: Jamb A · B · C (flange 18 · depth 20 · top 74), Sill D · E · F (wall flange 15 · projection 21 · drip 15), Head G · H · I (lower leg 15 · fin 20.75 · wall flange 30.5).
- Leave the box and click Apply. Only the windows of that panel change; the other panels and the material stay the same.
- A box you empty goes back to the default.
- Every size must be at least twice the sheet thickness and at most 300 mm; the head wall flange (I) must be at least 0.5 mm + two sheet thicknesses longer than the lower leg (G). A value that does not comply is not saved; the status bar gives the reason.
- This section is visible only on opening-aware trapezoid and with a panel selected.
- The 3D model, the cutting band of the trapezoid, the cladding work order, the fabrication sheet and the material list use the same size.
Door and window casing panel
To size the casing of a single window or door separately, use the Door and window casing panel on the right-hand strip.
- To open the panel, click its icon on the right-hand strip or, with cladding on, click the casing, sill or head of a window or the Omega of a door in 3D. The selected casing is outlined with a thin line.
- In the Doors and windows in the project list at the top of the panel, every panel that has opening-aware trapezoid is listed with its doors and windows below it; "custom" appears next to the ones that have their own value. Clicking a row in the list is the same as clicking in 3D.
- For a window, the panel has the section diagrams of the casing, sill and head with the letters A–I and nine size boxes; clicking a letter takes you to its box. Below them the Jamb sheet, Sill sheet and Head sheet boxes show the sheet of that window.
- Type the value and click Apply: the size is written only to that window (one undo step); other windows on the same panel do not change.
- The line below tells you where the size comes from: specific to this window, the size of the panel or the default. The Applied line shows the actual size built by the rule (for a window, the left and right casing top and the sill / head length; for a door, the left and right Omega leg).
- Back to panel deletes the window's own size; Discard drops a change that has not been applied.
- A sheet thickness equal to the one in the material does not create a record; a different thickness is written only to that window.
- Two twin windows with different sizes or sheets are framed separately.
Door Omega. When you click the Omega of a door, or the door in the list, the Door Omega section opens in the panel. In the diagram J is the leg, K the height, L the trough and M the flange; separate values are entered for each edge in the Left and Right columns:
- J · leg (mm, 0 = automatic): if you leave 0, the leg is calculated from the cutting band.
- K · height, outer (mm) (21), L · trough, outer (mm) (28), M · flange (mm) (25) and Omega sheet (mm).
- If the right column is the same as the left, the right edge does not create a separate record. If the Omegas of the two edges differ, they become separate marks in fabrication.
- Apply writes only to that door; Back to default returns the sizes to the default and the sheet to the material.
Trapezoid screws
The screw that fixes the trapezoidal sheet to the frame comes from the screw rule of the material (see the "Cladding Consumables" topic). The pattern is as follows:
- The sheet is screwed to every horizontal profile that crosses it: bottom flange, top flange, intermediate rails, head and sill. A screw goes only into a rib that has a profile under it: the head and sill are screwed only along the window.
- How many ribs apart a screw goes is decided by the spacing of the rule (spacing ÷ rib). For one screw in every rib, type the spacing equal to the rib (169 mm on Trapezoid 19/1000 D).
- The screw is in the middle of the profile flange the sheet touches, and it falls in the middle of the valley (or crest) of the sheet itself.
Screw position is chosen in the Joint and edge tab of the material:
- In the valley (face on the frame) (default): screws go through the face of the sheet that sits on the frame; there are no screws on the rib crest.
- On the crest: screws go through the rib crest; a sealing washer and a screw as long as the rib height are needed.
The screw count, the screw marks in 3D and the screw length are calculated according to the choice.
Editing sheets by hand
If the automatic layout does not suit you, you can change the sheets one by one.
- Select the panel; in the Cladding panel choose the sheet from the Sheet list in the Ribbed sheet › Selected sheet section, or Alt + click the sheet in 3D.
- Fill in the boxes: Start (mm) (distance of the sheet from the panel start), Width (ribs) (the number of ribs of a full sheet is a full sheet, fewer is a narrow sheet cut lengthwise; on Trapezoid 19/1000 D 6 = full sheet, 3 = 527 mm), Bottom level (mm) and Top level (mm) (where the sheet starts and ends measured from the bottom of the panel; if you leave them empty, the sheet extends to the end of the cladding at that end). With a horizontal layout these two boxes are called Length start (mm) and Length end (mm) and are measured from the panel start.
- For two sheets one above the other, click Add sheet above: the new sheet overlaps the one below by the End lap of the material (default 150 mm).
- Save with Apply. Back to automatic deletes the changes made by hand and recalculates the layout with the rule of the material.
Example: on a 3000 mm high panel the window is between 1000 and 2200. For a single sheet over the window, select the sheet and type 2200 in Bottom level: the sheet comes out 800 mm long. For two sheets one above the other, set the Top level of the lower one to 1800 and click Add sheet above: the upper sheet starts at 1650.
- The first change by hand fixes the current layout of the panel. Fixed sheets are not recalculated when the panel length or the doors/windows change; the part that goes beyond the panel is cut.
- A gap is not rejected: the Cladding panel and Cladding Validation warn "… m² is left uncovered." It is possible to leave part of a panel uncovered on purpose.
- Ctrl + Alt + click in 3D selects a single sheet. With a sheet selected, Delete deletes the sheet; the arrow keys (← → with a vertical layout, ↑ ↓ with a horizontal layout) shift the joint by one rib.
- The cutting list, the cladding work order, the screw count, the material list and the 3D view all read from the same sheets.
Defining a cladding material
Cladding materials are in the company library and apply to all projects: the Cladding materials page of the ⚙ Settings › Company libraries › Materials & Sections window. Changes are written with Save changes at the bottom.
A row of the table is one product: Product name, Manufacturer, Product code, Material type (Board, Trapezoidal / ribbed sheet, Sandwich panel, Membrane, Insulation, Tape, Accessory, Fastener), Sheet/board thickness, Mounting depth, Screw diameter (mm), Screw length (mm) and Screw head (screws only), Panel side margin (empty = 25 for boards), Colour, Unit (m², lin. m, pcs) and Layout mode. Choose the colour from the Colour of the selected product list below the table or type it in the Code box. Restore defaults brings back the list that comes with the program.
The Joint and edge tab:
- Joint type (No joint, Butt gap, Lap, Continuous) and Edge behaviour ("Board edges and corners" above).
- Width-direction joint (mm) and Length-direction joint (mm): the open joint between neighbouring and stacked sheets.
- Allow 90° rotation in the cutting layout: switch it off for a material that has a direction.
- Roof sheet matching may turn 180°: allows a part to be turned end over end in the Get cut sheets out of one sheet option of Create Roof. If the two edges of the sheet differ, the lap of the turned part reverses; off by default.
- Extra overlap ribs: 0 is the standard overlap; if you type 1–3, a single sheet joint is overlapped by at most that many extra ribs.
- Board layout (From the edge / From the centre), Narrowest end piece (mm), End joints (Aligned / Staggered).
- Saw kerf: the material taken away by each cut (mm). In the cutting plan this much gap is left between pieces; 0 = no allowance. Enter the kerf thickness of your machine (for example 4 mm).
- End lap (mm): the length by which the upper sheet overlaps the lower one when two trapezoid sheets are stacked.
- Trapezoidal layout (Sequential / Opening-aware) and Do not rip strips (overlap full sheets).
- Casing sheet, Sill sheet, Head sheet, Door Omega sheet and Screw position (above).
The Stock sizes tab holds the sizes you buy: Name, Total width (mm), Length (mm), Effective width (mm); Lap (mm) is calculated as total width − effective width. It is edited with the Add stock and Delete selected buttons.
The Trapezoidal / custom section tab defines the section of the ribbed sheet:
- Select the material in the table and set Material type to Trapezoidal / ribbed sheet.
- Choose the Visible face: Wide face outside (crowns to the frame) or Crowns outside (wide face to the frame).
- Choose a ready-made section from the Program section library and click Apply, or choose a Section type (Flat, Standard trapezoid, Custom periodic section) and enter the sizes: Section width / period (mm), Height (mm), Crest width (mm), Web angle (°), Edge phase (mm). Base width is calculated from the angle.
- For a custom section, enter the points in the Custom periodic section points (X, Z) table on the right, or take an open polyline of one rib from a file with Import DXF / CSV section.... The preview shows the rib produced by the numbers.
- Click Save changes; an imported section is also written to the library with this button.
Project-specific trapezoid stock length. Enter the length in which you buy the trapezoid as sheet in this project, per material, in the Stock lengths tab of the PROJECT › Project Info › Project Settings window (for example 6000 or 7000 mm). For a material left empty, the catalogue sheet length is used. The project cutting plan and material list calculate with this length (see the "Output Centre" topic).
Production outputs and the offcut pool
- The Production outputs (Output centre) button below the Cladding panel opens the Output centre, which produces the cladding work order, the cutting layout, the casing fabrication and other outputs (see the "Output Centre" topic).
- Add offcuts to the pool adds the cutting offcuts of the selected panels to the permanent offcut pool; later layouts take from these offcuts first. This is not an output but a library operation.
- Whether the cladding is ready for production is checked by PRODUCTION & OUTPUT › Production readiness › Cladding Validation (see the "Production Readiness" topic).