The framing is the steel skeleton of the panel: bottom and top track, studs, noggins, the profiles around doors/windows and braces. The program builds the framing by itself from the panel size and the rules on the Properties › Framing tab; you change the rule, and the profiles are laid out again.

Parts of the Framing

Light steel profile is mostly C-section: the wide face in the middle is the web, the wings on both sides are the flanges, the small returns at the ends of the flanges are the lips.

  • Track (rail): the horizontal profile running along the whole bottom and top of the panel. The studs sit inside the track.
  • Stud: a vertical profile between the tracks. The end studs at both ends of the panel are always built.
  • Noggin (girt): a horizontal intermediate profile between studs.
  • King stud (jamb): the full-height stud on both sides of a door or window.
  • Header and sill: the horizontal profile above the opening and below the window.
  • Cripple stud: the short studs below the sill and above the header (in lists its role appears as Cripple).
  • Header lattice: zigzag braces filling the area above the opening.
  • Backing: an extra stud against which the other panel abuts at a corner and T joint.

Parametric and Frozen Framing

The state of the framing is written in the Properties › Framing › Framing mode section.

  • Framing: parametric (generated from dimensions): when the panel size, a door/window or a rule changes, the profiles are rebuilt by themselves. Every panel you draw starts like this.
  • The Freeze framing button fixes the profiles where they are. After that you can move and delete them one by one, but they do not update by themselves when the panel size changes.
  • Back to parametric deletes the fixed profiles and regenerates the framing from the dimensions; it asks for confirmation first.
  • Update Panel from Profiles appears in this section only while a frozen or imported panel is selected. It derives the panel boundary and the door/window openings again from the profiles you changed by hand. If several panels are selected it applies to all of them; the result is written panel by panel in a window.
  • Imported panels (.axd, .tcf) come as Framing: imported; these also count as frozen.
  • If you change by hand a profile built by the program in a parametric panel (cut, trim, extend, move an end, flip the profile, move), the panel is frozen by itself. Profiles you add by hand are kept in a parametric panel too.

PANEL › Framing Group

  • Generate Framing (short name KU): regenerates the framing of the selected panels from the rules; the identity of existing profiles is kept. Use it to update panels after a machine or rule has changed. In a frozen panel the profiles stay as they are. The number of new, updated, removed and unchanged profiles is written to the status bar. If you do not like the result, a single undo step takes you back. Skipped parts and warnings are written to the status bar and the history of the command line.
  • Flip Member 180° (R): turns the selected profile upside down around its own axis; if a panel rather than a profile is selected, it flips all profiles of the panel. Details are below in the section "Mouth and Direction of a Profile".
  • Flip Joist Direction: in the selected roof, floor and ceiling panels, switches the direction in which joists are laid between local Y and local X. The place, openings and dimensions of the panel do not change; panels with fixed framing are skipped.

How the Framing Is Built

On a wall the order is: first the tracks, then the door/window frame (jambs, header, sill), then the stud grid in the remaining empty space, and last the noggins and the header lattice.

  • A grid stud that falls inside the opening or on the flange of the jamb is not built; the gap between the jamb and the next stud may slightly exceed one stud spacing.
  • The jamb, header and sill are always a single profile whose web faces the opening. Door and window dimensions are given to the outer face of the web of these profiles; that is why the net opening comes out right.
  • Cripple studs are in line with the studs of the panel: those below the sill and those above the header stand in line. A line that falls too close to the jamb is skipped.
  • There is no separate threshold profile under a door; the profile under the door is the bottom track itself. Whether the bottom track passes under the door is decided by the Sill profile column of the Doors and windows tab (see "Doors and Windows").
  • The header lattice is built only on doors and windows, if there is enough room above the opening. To turn it off, click the Framing row of the panel in the Project Explorer; in the BIM and details section above Properties uncheck Generate a header lattice above windows/doors and press Apply Recipe.
  • In a panel with a slanted or gabled top edge, the studs, jambs and cripple studs end at the slanted edge where they are; they do not go up to the highest point of the panel.
  • In roof, floor and ceiling panels the joists are laid along the panel. On the edge parallel to the joists there is an edge joist, on the other edges there is a perimeter profile; slanted edges are closed with the perimeter profile. The openings in these panels are framed with jamb, header, sill and lattice as on a wall.
  • Inner profiles end on the sheet of the opposite profile; the outer size of the panel does not change. The machine cut of the profiles is always a straight 90° cut.
  • The assembly clearance is not entered in the panel; it is in the profile mapping of the machine (see "Machine Settings").

Spacings: Vertical (Studs) and Horizontal (Noggins)

On the Properties › Framing tab there is a Vertical (studs) section for studs and a Horizontal (noggins) section for noggins. In each section a layout mode is chosen:

  • By sheet size: a fixed step comes from the entered board size; for studs Cladding width, for noggins Cladding length is entered, as well as Gap between cladding and Cladding spacings per sheet (how many spacings per board). Joints fall on multiples of the board size; it does not know the edge allowance or the door/window.
  • By cladding joints: profiles are placed under the real joints of the boards on the panel; the joint falls in the middle of the flange of the profile so that both boards are screwed. Edge allowances, doors/windows, corner overhang and staggered layout are taken into account. Maximum spacing (0 = joints only) divides the space between the joints equally. Ribbed trapezoid sheet gives no joint because it is joined by overlap; a panel without cladding is divided equally by the maximum spacing.
  • First – Other: the first spacing is separate, the following ones are fixed (if the first cell is different because of the edge profile).
  • Equal spacing: divides the panel equally without exceeding the Maximum value; no narrow cell is left at the end.
  • None: only the frame, no intermediate studs or noggins.

More options:

  • Back-to-back double stud (vertical) and Back-to-back (horizontal): two profiles back to back are placed at each position.
  • Staggered (horizontal): the noggins are shifted in the neighbouring cell and do not stay in one line. The box next to it is the shift distance (0 = half a step).
  • Continuous girt (cuts the stud): the noggin is not split at the studs, it is a single piece along the whole length; at every stud it passes (including jamb, support and cripple studs) a notch is cut in the noggin and a screw is placed at the crossing. The studs are not cut. While Staggered is checked, this box is dimmed.

Other places that ask for a single spacing number (for example the purlin spacing in Create Roof) also write to this rule: if the mode is By sheet size or First – Other and another number is typed, the rule switches to Equal spacing.

Joist Direction (Roof, Floor, Ceiling)

By default joists are laid in the local Y direction of the panel (the direction of the Y arrow on the panel; on a sloped roof from the eave to the ridge). In the Joist direction (roof, floor, ceiling) section choose Along local Y or Along local X and press Apply below; it applies to several panels together. The quick way is PANEL › Framing › Flip Joist Direction. On walls and trusses this choice is disabled.

Brace and Lattice Settings

The Panel brace recipe section determines the shape of braces and lattices. These settings are written to a draft; they are saved with Apply below.

  • For header: the pattern of the header lattice and of the Horizontal Brace tool. Options: Warren / zigzag, Inverted Warren, Warren with verticals, K · to centre, K · outward, Parallel rising, Parallel falling, Inner chord with posts.
  • With Inner chord with posts chosen for the header, a zigzag lattice is built above the door/window; its top chord is two back-to-back profiles (the lower one mouth down, the upper one mouth up) and short posts run from the lattice tops to the top plate of the wall, entering the mouth of the upper profile. The height of the chord above the header is the value in the Header height box; any size can be entered. If the chord is high enough to reach the top plate of the wall, no separate chord is added and the top plate acts as the chord. A lattice placed in a single bay with the Horizontal Brace tool is Warren in this layout.
  • Vertical lattice pattern (in a truss and beam Truss / beam bracing): the pattern of the Vertical Brace tool and the truss lattice. Warren with verticals puts an intermediate profile at the nodes; the braces end on both sides of it.
  • As a vertical pattern, Inner chord with posts can be chosen only for a truss. A horizontal inner chord runs through the whole truss: below the chord the web is a V lattice together with the bottom chord (the V tops come under the purlins); above the chord a vertical post runs from under each purlin to the top chord. No post or V top is placed at a purlin point closer than 150 mm to the end of the chord, nor where the room between the chord and the top chord is less than the profile depth. The ends of the chord enter the mouth of the sloping top chord with a square cut; no angled cut is made. Inner chord height is the height of the chord above the lowest point of the truss (default 500 mm). With Double back-to-back inner chord on, the chord is two back-to-back profiles; with it off, a single profile. These two boxes are enabled only for this layout; if the chord is too high to stay inside the truss, the framing is not generated and a warning appears. A truss with a different chord height or single/double choice does not share the mark of the others even if its outline is the same; its mark is given in the usual sequence (e.g. M3 if M1 and M2 exist).
  • Target brace angle (°), Other brace end gap · minimum (end gap of single braces), Header height (from the header to the top chord of the lattice) and Lattice net end gap (mm) (the assembly gap between the ends of lattice braces meeting at the same node, default 2 mm).
  • Lattice intermediate posts (except vertical lattice) and Vertical lattice posts: whether an intermediate post is placed at the lattice nodes.
  • In a truss and beam there are also Purlin spacing (mm) and Purlin distribution (see "Create Roof, Truss, Dormer and Railing").

The Profile brace limits section: Smallest angle (°), Largest angle (°) and Truss diagonal minimum angle (°) (a diagonal in a truss cell cannot be narrower than this to the horizontal, the vertical or the chord; if it does not fit, a post is placed in the middle of the cell; 0 turns the rule off). A new truss built by Create roof or the Truss command takes the Smallest angle for it (35°): a diagonal that cannot keep the angle at the truss end is replaced by a post. Trusses built earlier keep their own value. The changes are applied when the framing is regenerated.

Steel Strap Settings

A steel strap is a thin flat sheet brace screwed to the panel face instead of a profile (for its tool see "Adding Members and Braces"). Its settings are in the Properties › Framing › Steel strap (panel face) section; they are written with Apply below.

  • Strap width (mm) and Sheet thickness (mm) apply to all straps in the panel (except a strap with its own size). When the panel section changes, the strap does not return to a profile; it sits on the face of the new web.
  • Face A horizontal strap levels (mm) and Face B horizontal strap levels (mm): dimensions from the bottom of the panel to the middle of the strap. The program lays a horizontal strap along the whole length on that face; the strap is cut at doors/windows and ends at the edge stud of the opening.
  • Face A vertical strap positions (mm) and Face B vertical strap positions (mm): dimensions from the start of the panel. The strap sits on the stud nearest to the given position and runs from the bottom horizontal profile to the top one.
  • Separate the dimensions with a space (1200 2400); ; also works, and the decimal can be a comma or a point. One strap is placed for every dimension you type. If the box is empty, there is no strap on that face in that direction. Example: a 3000 mm panel, a window between 900 and 2100, face A levels 1200 2400 → at 1200 two pieces on both sides of the window, at 2400 a single piece of 3000 mm.
  • The row straps are laid again every time the framing is renewed; straps placed by hand are not touched. Flip faces also swaps the A and B boxes.

To make a single strap different, select the strap with Alt + click; under the section the boxes This strap's width, This strap's thickness, Start X / Y and End X / Y open (the ends are in mm from the bottom left corner of the panel). Type the value and press Apply. If the width or thickness box is empty, the strap follows the size of the panel. Limits: width 10–1000 mm, thickness 0.1–10 mm, length at least 50 mm.

Steel straps and gusset plates are shown green in the model view, whatever the colour of the panel.

Gusset-plate X bracing: while the Gusset-plate X bracing box in the same section is on, a gusset plate is placed at the ends of every diagonal steel strap in the panel (placed diagonally with X Brace or one by one with Steel Strap); the plates appear as soon as the strap is placed. The plate is screwed to the stud and the track, and the strap lies on top of the plate. The corner of the plate is at the corner where the stud meets the track, and the end of the strap stays on the plate; Gusset plate width is measured along the panel and Gusset plate height along the panel height. The default is 150 × 150 mm with a thickness of 2 mm; width and height can be 50–1000 mm, thickness 0.5–10 mm.

  • If Blocking and strap at the crossing is ticked, a row of horizontal noggins as wide as the X, with a horizontal steel strap along it, is placed at the height where the two straps of the X cross. If there is already a noggin at that height, a second one is not placed.
  • Crossing bolt hole: if a diameter in mm is entered (3–30 mm; e.g. 13 for an M12 bolt), a bolt hole is made where the two straps of the X cross. The hole goes through both straps and the flange of the frame member behind; the hole in the member goes into the machine file as a flange hole (the active machine needs a flange hole die of that size). If a horizontal noggin is placed at the crossing, the noggin is positioned so that the middle of its flange is exactly on the crossing, and the hole is made right in the centre. If a stud or an existing noggin is behind the crossing, the hole is made in the middle of that member's flange, at most half a flange away from the crossing. If there is no member behind it at all, the hole is made only in the two straps. The bolt appears as a hexagon bolt head in the model view and as Ø with the diameter on the panel sheet. The box comes with 12 mm; in older projects with the gusset plate on, a 12 mm hole is also made when the framing is regenerated. If you do not want a hole, enter 0 (or clear the box). The bolts are counted in the project material list on a separate row from the screws, one row per diameter ("X crossing bolt (hole Ø12 mm)"); nuts and washers are not counted separately.
  • Nog and stud under plate edges (on by default): two edges of a gusset plate sit on the corner stud and track; members are placed under the other two edges so they are not left free. Under the horizontal edge a noggin runs from the corner stud to the nearest stud beyond the plate; it does not run the full panel length. Under the vertical edge a short stud runs from the track the plate sits on up to the nearest horizontal member in that direction (usually that noggin). The body of each member stays inside the plate, and the plate edge lines up with the outer edge of the flange. Where a member already lies under the edge (a grid stud or noggin at that line), no new one is added. If the strap end is away from the corner and the plate does not sit on a frame corner, no edge members are added. Turning the box off removes these members.
  • The parts derive from the X strap: when you move or delete the strap, or turn the box off, the parts go with it. The change is written with Apply below; if several panels are selected, it applies to all of them.
  • The gusset plate appears in the production list as a flat sheet part; it does not go into the machine file and is cut separately. In the lists a steel strap is written as "FLAT STRAP 100x1.2" (width × thickness) and a gusset plate as "GUSSET PLATE 150x150x2" (width × height × thickness); each size is a separate row.
  • While the box is on, an X strap whose end stops inside the corner is pulled to the corner where the stud meets the track; the axis of the strap runs from corner to corner. A strap end that runs past the panel is shown trimmed at the panel edge; in the workshop the strap is cut along its axis and the pointed end is cut to the panel edge.
  • Screws: four rows take the screw type and count: Plate screw (per gusset plate), Strap end screw (per strap end), Stud screw (at every intermediate stud the X strap passes over; the short studs at the plate edges count too) and Crossing strap screw (per stud in the horizontal strap at the crossing height). The type is chosen from the material cards of the quantity library; if none is chosen, the list writes a general name. The program counts the plates, strap ends and studs itself; the total goes into the project material list and, in the shipping list, under the panel. If the count is 0, no screws are counted at that place. The plate screws are shared equally among the members under the plate: the corner stud, the track and (when on) the noggin and short stud at the plate edges; e.g. with 8 screws and four edge members each gets 2, and without edge members half go to the stud and half to the track. The screws go to the middle of the member flanges; the stud and crossing strap screws go to the middle of the stud flange, spread across the width of the strap. The strap end screws are spread along the strap: Strap end: first screw / spacing is the distance of the first screw from the end and the distance between the screws (default 20 and 25 mm), Strap end: rows / row spacing is 1 or 2 rows and the distance between the two rows (default 1 row, 20 mm). The screws appear as dark screw heads in the model view and as screw symbols on the panel sheet; their counts are written in the fastener table of the sheet and in the Bracing screws section of the panel fabrication work order. The Sheet parts (cut by hand) section of the work order lists the steel straps and gusset plates with their size, length and count.
  • A hold-down is not part of this option; place it on the stud by hand from the Joints and operations › Foundation connection section.

Truss apex plate: with a truss selected, turn on Put a steel plate on both faces at the apex in the Truss apex plate section under Properties › Framing, and a flat steel plate goes on face A and face B at the apex of the truss. You do not type the plate size: it follows the apex point of the truss and the top chord profile. The plate reaches 3 times the depth of the top chord profile horizontally on each side of the apex and stays at least one profile depth away from the heel; its top edge is at the apex point, and its bottom edge is half a profile depth below the inner face of the top chord at both ends of the plate, never down on the bottom chord. The upper corners of the plate are cut along the roof line (a pentagon); cutting and weight count the rectangular sheet. You give only the Plate thickness (0.5–10 mm, default 2 mm) and the screws. The plate is placed only on a gable (two-slope) truss with enough room at the apex; if it cannot be placed, the summary under the section says why, otherwise it gives the number and size of the plates. The setting belongs to each truss: select the trusses you want and turn the box on; Apply below writes the change to the selected trusses only. If you choose plate screws into the top chord (a count of 1 or more), the plate carries the connection: the machine does not put its own screws that join the top chords at the apex; if you also choose screws into the king post, the machine screws that join the post to the chords are left out too. The cutting and swaging operations at the member ends stay as they are, and Joint Check shows these ends as connected. With a screw count of 0 the machine screws stay in place.

  • Screws: two rows take the screw type and count: To top chord (per top chord end on one plate; each plate is screwed to two chords) and To king post (per plate; not counted when the apex has no post). The type is chosen from the material cards of the quantity library and the count is typed; if the count is 0, no screws are counted at that place. The program counts the plates and chord ends itself; the total goes into the project material list and, in the shipping list, under the panel. The screws appear in the model view and on the panel sheet; their counts are written in the fastener table of the sheet and in the Bracing screws section of the panel fabrication work order.
  • Like a gusset plate, the plate is a flat sheet part: it gets a mark number and is listed with the truss it is used in, in the quantities, the cut list, the panel sheet and the Sheet parts (cut by hand) section of the work order; it does not go into the machine file and is cut separately. It is shown green in the model view like the steel straps. The plates derive from the truss: when the shape of the truss changes, their size follows, and they go when the box is turned off.

Mouth and Direction of a Profile

The open side of a C profile (the side with the lips) is called the mouth, the closed side (the web) the back. Which way the mouth faces decides the joint: if the end of a profile enters the mouth of the opposite profile, a crimp (squeezing the profile end inward) is made at the end and a lip cut on the opposite profile; if it rests on the back, a notch and an ear cut are made at the end.

  • The program turns the mouth of the tracks and perimeter profiles toward the inside of the panel; the web of the jamb, header and sill faces the opening.
  • Select the profile that stands the wrong way and press R, or use PANEL › Framing › Flip Member 180° (R). Use Alt + click to select a profile, add several profiles with Ctrl. Typing R in the command line and pressing Enter does the same job.
  • In the right-click menu there is Rotate profile (180°); on a panel there is Rotate all profiles of the panel (180°). If a whole panel comes upside down in imported files, this way helps.
  • For another rotation such as a quarter turn, use the Orientation (Quarter turns) box in the right-click › Profile Properties window.
  • Adding a brace does not change the direction of neighbouring profiles; a profile turns only when you flip it.

If there is an active machine, the machine operations of the profiles are visible in the model: holes, notch, lip cut and corner rounding are drawn as cuts; the crimp is painted orange and the flattening yellow. To keep the model light, operations are drawn only on the selected panel and, when you zoom in, on the panels nearest to where you look; from a distance the profiles look plain. The drawing updates by itself shortly after the camera stops; sheets and the machine file always contain every operation. To see the operations on every panel, set 3D detail to Full (see the 3D detail topic below).

Section and Material

  • The section of the panel is chosen from the Properties › General › Profile and material › Profile (library) list; in the list the real size (web × flange × lip × sheet) is written next to the name.
  • Steel grade and Galvanised coating class come from the selected section record and are only shown here. To change them, choose another section record or edit the grade and coating of the record in ⚙ Settings › Company libraries › Materials & Sections (see "Material and Section Library"). The panel manufacturing sheet writes it together with the yield strength.
  • Not every profile in a panel has to have the same section: right-click a profile and type the web, flange, lip and sheet size in the Section part of the Profile Properties window. If left empty, the section of the panel applies.
  • A steel strap carries no profile section; changing the panel section does not affect the straps.

Frame Connections and Double Tab

The screws of the frame connections are in the Properties › Joints and operations tab. The settings in this tab are written with Apply below; only the fields you changed pass to all selected panels.

  • Frame connections › Connection fastener pattern: One per flange (2 per connection) or Flange multi-fastener: 5 per flange (10 per connection). It applies to all joints, including braces.
  • Fastener: Screw / rivet or Bolt.
  • Fastener product: the quantity card of the frame screw of the panel (for example "Self-drilling screw 4.8×19"). The options are the cards in QUANTITIES › Materials › Material Cards; first open the card there. The Material List, the panel sheet and the screw list use the name and price of this product. The hole diameter and the height from the web come from the die in Machine Settings; choosing a product does not change it.
  • Double tab (chassis): only in a floor/chassis panel. When the end of a profile rests on the middle of the perimeter profile, a two-eared tab is opened in the perimeter profile; the ears are cut from the web and bent 90°, and the entering profile is screwed to them on site. For Perpendicular connection and Angled connection separately Do not apply or Apply at end-to-mid connections is chosen. It is not opened at a corner; if the machine has no double-tab die, it is not opened at all. The screw is still placed.
  • The Profile operations (sent to the machine) list shows all operations opened on the profiles (place, size, source); to see all of one profile, select the profile with Alt + click. The list comes from the same source as the production file. If there is no active machine, no operation is produced.

Foundation Connection (Anchors and Hold-Down)

The anchors that connect the bottom track of a wall panel to the concrete are set up in the Properties › Joints and operations › Foundation connection section.

  1. First open the Foundation connection library with the Types… button and enter your own products on the Anchors tab: kind (Chemical anchor, Mechanical anchor, Cast-in bolt, Concrete nail), diameter, length, embedment, hole, washer dimensions, washer grade (e.g. S235, may be left empty; added to the washer name in the material list) and product code (material card). The library is valid for all projects and is empty at first opening. Save it with Save.
  2. Select the panel, check the Anchor the bottom track to the foundation box, choose the Anchor type.
  3. Enter the Largest spacing and Distance from stud values from your structural calculation or company rule; the program does not suggest a value.
  4. If you wish, choose Anchors beside openings and Sill sealer (the material card of the strip laid under the bottom track), and press Apply.
  • The rule: one anchor at both ends of each bottom track piece, on both sides of openings (outside the king stud) and next to a stud where the spacing is exceeded. An anchor never falls on the flange of any stud; two anchors are never closer than 100 mm. The line under the section writes how many anchors were placed.
  • For every anchor a bolt hole is opened in the web of the bottom track and goes to the machine file; its diameter comes from the die of the machine. For the Concrete nail kind no hole is made.
  • The anchor positions are not stored; they derive from the studs and are placed again when the panel size, spacing or an opening changes. To correct one by one press Add / remove anchor; the cursor turns into the pick box. Pick a stud: an anchor beside it is removed, otherwise an anchor is added on the side of the stud you clicked (Esc ends). Manual corrections stay when the panel is rebuilt.
  • Hold-down (tension bracket): define your product on the Types… › Hold-down tab (Plain angle or Gusseted angle, dimensions, number of screws, rod diameter and length, rod distance, steel grade). The steel grade (e.g. S320GD) may be left empty; if entered, it is written to the angle and the gussets and appears in the material line of the press work order. Choose the Hold-down type and press Add / remove hold-down; the cursor turns into the pick box. Pick a stud: if there is no hold-down it is added on the side of the stud you clicked, if there is one it is removed. Only studs standing on the bottom track can be picked. Its place is decided by your structural calculation.
  • Place Anchors (CHECK › Regulation): places hold-downs where the Turkish light-steel building regulation asks for them: on the two end studs of every wall segment that carries lateral load. A panel carries lateral load when it has structural sheathing or a brace that is one piece from the bottom track to the top track; every segment at least 300 mm wide counts. First choose the hold-down type (if the library has a single type, that one is used). The selected panels, or every wall when nothing is selected, are examined; the studs that will get a hold-down are shown and your confirmation is asked. If there are panels the regulation asks no anchors for, you are first asked whether to place them there too: if you answer Yes they are planned by the same rule and listed separately in the confirmation as "at your request". Ends that already have a hold-down are left as they are. It is all one undo step. The capacity of the hold-down must be confirmed by your structural calculation.
  • Anchors and hold-downs are visible in 3D. The anchor, washer, sill sealer and hold-down go into the material list; the anchor and hold-down go into the connection list of the panel sheet. The anchor and hold-down positions of the whole project are obtained with the Anchor setting-out plan output (see "Output Centre").