Guide topics

26

Light Steel File Import (.axd / .tcf)

PROJECT › Get Data › Import brings a light steel drawing file (.axd or .tcf) in as panels with framing. The profiles stay where they are in the file; they can be selected, edited and go into production.

Step by step

  1. Press PROJECT › Get Data › Import and choose the .axd or .tcf file.
  2. In the confirmation box that opens, see the number of profiles in the file, the total length and how many panels will be built. If there are panels in the project they are kept, the new ones are added.
  3. Press OK. The panels are built and the screen zooms to them.
  4. Read the Import report: the panels created, the number of profiles, total length, the number of doors and windows extracted from the framing, the steel grade, the count and length per section, the panel marks in the file and warnings.
  5. Save the project at once; you do not need to import the file again.
  • The import is a single undo step: Ctrl+Z undoes all the imported panels.
  • On large files the import may take long; the program does not respond until it finishes.

What is read from the file

  • Panels are separated as in the file. If the file says which panel each profile belongs to (the TCF panel record, the AXD object link), the panels are built by this link and the panel name (e.g. DP-1, IP-12) comes from the panel record in the file. Profiles whose link cannot be read are grouped by their position on the same wall line; the report says this, and in that case check the panel boundaries.
  • If panel names were assigned from the file by position or in file order, the report says so. Names assigned in file order are a guess; check the panel names before sending to production.
  • Profile direction is read from the file. The AXD profile record carries the direction the opening of a C profile faces; the openings of tracks, studs, noggings and braces are built by this direction, so the drawing, the joint ends and production see the same opening. In a file with no direction information, the bottom track opening faces up, the top track and nogging opening faces down, and the edge stud faces the inside of the panel.
  • Profile roles and door/window openings come from the file. If the profile record carries a role (frame, infill, opening, connection, brace), the opening profiles come as header, sill and jamb: each header is an opening; if there is a sill under it, it is a window, otherwise a door. In a file with no role information, the openings are extracted from the framing; the report gives how many openings were found.
  • The panel outline comes from the outer line in the file. A gable wall with a sloped top edge, a triangular piece and a panel with a step on top are built in their shape in the file. If the file draws the door as a notch opened from below at the boundary and there is a door opening there, the notch is closed and the door remains as an opening. If the line does not coincide with the profiles, or the panel is a sloped roof or floor panel, the panel stays rectangular. The report says how many panels have outlines built from the file.
  • Panel type (wall, roof, floor, ceiling, truss) is understood from the layer name in the file or the shape of the panel; panels on a sloped plane become roof panels. Panels are put on separate import layers by type.
  • Section, sheet thickness and steel grade are taken from the profiles in the file.
  • ARKİTEK and BADE CAD `.axd` files open. A BADE CAD file writes no section name or steel grade: the section is built from the dimensions in the file (e.g. 90 x 47 x 12 x 1.2) and the steel grade comes empty; check the steel grade of the profiles after the import. The panel link, panel name, outline, profile direction and role are read from a BADE CAD file too.

Editing imported panels

  • The imported framing is fixed: the profiles in the file are kept as they are, the program does not regenerate them with its own rules.
  • When you apply cladding, layer, name or a door/window table to these panels from Properties, Apply asks three options: Yes deletes the existing profiles and regenerates the framing from the panel recipe; No keeps the framing as it is and applies the cladding, layer, name and other changes; Cancel applies nothing.
  • If the section was not changed, the profiles' own sections are not touched; framing mixed 1.0 and 1.5 mm stays as it is.
  • To split a panel that was merged too much during import into its parts, use PANEL › Split / Merge Panels › Split Panel (see the "Panel Editing and Splitting" topic).

Caution

  • On a panel where the brace layout does not fit the nodes in the file, the braces are left as in the file and the report says so; check that panel before production.
  • If a panel gives an error while being imported, the remaining panels are still imported; the name of the faulty panel is in the warnings of the report, check that panel.
  • If the IFC file of the same drawing carries no panel information (only a profile list), take the panels from the .axd or .tcf file instead of the IFC.