The Output centre takes all production and project outputs from a single window with a single button: the machine file, work orders, lists, cladding layouts, sheets and the 3D model. File names are not asked one by one; you choose a folder and all the outputs you ticked are written there.

Step by step

  1. If you want the output of only some panels, select them in the model first.
  2. Press PRODUCTION & OUTPUT › Output › Output centre.
  3. At the top choose the Scope: Whole project or Selected panels.
  4. Press one of the Package buttons, or tick the outputs in the list one by one.
  5. Look at the preflight box at the top right: if it is red, there is a blocking error (below).
  6. On the right, check Paper, Machine and Target folder.
  7. Press Produce all.

The results appear just above the Produce all button in the Results list: next to each output, how many files were written (✔), and if it failed, the reason (✖). Double-clicking a row shows the file in the folder; if Open the folder when done is ticked, the folder opens by itself. The bottom line says how many files were produced.

Scope

  • Whole project uses all panels.
  • Selected panels uses only the panels selected in the model. If panels are selected in the model when the window opens, the scope is set to this automatically.
  • The machine file, production work order, cut list, cladding work order, nesting, offcut-pool nesting, casing fabrication, panel sheets, placement plan, panel list and screw list follow the scope: when a single panel is selected, only that panel is in the file.
  • Outputs that write the whole project (member work order, project-wide nesting, sheet set, anchor plan, material list, roof sheet list, 3D model, IFC) are not affected by the scope.

Packages

There are three ready packages:

  • Factory: machine file, member work order, cladding work order, nesting PDF, panel sheets. The panel sheets go to the workshop; the profile and sheet list of each panel is next to its sheet. The production work order PDF and the cut list are not in the package; tick them by hand if needed.
  • Customer: sheet set PDF, panel sheets, material list.
  • Site: placement plan, sheet set PDF, panel sheets, material list.

An output of the package that cannot be produced in that project (for example the member work order in a project without standalone profiles) is not ticked, and the package still appears under its own name. When you change the ticks by hand, the package becomes Custom. To keep your own combination, press Save package…, type the name in the box that opens and press Enter; the package is added as a new button. To delete a package you saved, right-click its button. Packages are in the user settings and are not written into the project.

Preflight check

When the window opens, the production preflight check runs by itself and writes the result in the box at the top right ("Preflight clean · 3 warnings" or "Preflight found 2 blocking issues; nothing is produced until they are fixed"). Open preflight shows the errors in the Production Validation window (see the "Production Readiness" topic).

  • Each output looks at its own area: if there is a blocking error in the framing, the machine file, production work order and screw list; if there is a blocking error in the cladding, the cut list, cladding work order and nesting cannot be produced. A cladding error does not stop the sheets, and a framing error does not stop the cladding work order.
  • An output that cannot be produced stays dimmed in the list and its reason is written next to it (for example "Frame preflight: 2 blocking issues").
  • The preflight check follows the scope: with Selected panels, only the errors of the selected panels are counted; an error in another panel does not stop the machine file of the selected panel. Outputs that write the whole project look at the project's preflight check in both scopes.
  • The preflight check is done with the machine selected in the Machine box on the right; when you change the machine, it is checked again and the state of the outputs is refreshed.
  • Warnings do not stop production.

Machine and shop

  • Machine file: written in the file format of the machine selected in the Machine box on the right (see the "Machine Settings" topic). Operation positions are calculated with that machine's dies. If no machine is defined, the row says "No machine defined — Machine settings"; if there is no framing in the panels in scope, generate the framing first.
  • Production work order PDF: one technical sheet per panel: the framing view, the framing profile cut list (net length and angle), joint and screw / rivet operations, cladding layers, cladding cuts and the consumables defined in the library. Below the summary the Panel frame weight is written (kg; the same calculation as the weight on the panel sheet: member length × weight per metre, by the steel grade of the panel); in a mark work order the total of all panels of the mark is written too. If the weight of a member cannot be calculated from its dimensions (sections other than C, U, Z, Sigma and steel strap), no total is written; the line says that a section's weight cannot be calculated. The Physical sheets and framing supports table gives the mark of each sheet (S1, S2…) and the profiles it rests on, and the Physical sheet seams table gives the pair of neighbouring sheets and the number of seam connections. The manufacturer name, logo, client, designer, sheet prefix and revision in the title block come from PROJECT › Project Info › Project Settings › İmalat Anteti (the Fabrication title block tab); if the logo is not found, the sheet is produced without a logo.
  • Member work order PDF (purlins, single members): gives all profiles that do not belong to a panel's framing (Create Roof purlins and valley beams, railing profiles…) in a single PDF. These profiles do not go into the machine file; they are cut in the workshop with this list. C, U, Z and Sigma members drawn with PANEL › Draw Member go to the machine file and are not on this list; Omega stays on it. Profiles are grouped under section headings; those with the same section, material, cut length, end cuts and holes are added up in one mark with a quantity: Create Roof purlins with the purlin prefix of the Number setting (A-1, A-2…; the placement plan writes the same code), other profiles P1, P2…. Each row gives the mark, quantity, material (grade and coating from the section record), cut length, start and end cut angle, number of holes, unit and total weight, total length and use (Purlin, Valley beam, the name you gave the profile, or Single member). There is a subtotal for each section, a grand total, and a total by section (quantity, metres, kg); hole positions are on a separate page. If there are no standalone profiles in the project, the row is dimmed.
  • Cut list: the cut parts of the cladding sheets (part code, panel, material, plate, size and position, barcode), the waste per material and the usable offcuts.
  • Screw / bolt list: the fasteners of the whole project: frame screws, brace screws and foundation anchors panel by panel, electrical box holder screws and cladding screws. At the end each type and diameter has its own total row, and the grand total comes last. When a single panel is selected only the rows of that panel are written. Roof covering screws come from the Screws per rib setting; trim screws are not counted in the model, so they are not in the list.

Cladding

  • Cladding work order PDF and Cladding work order DXF · 1:1: the sheet layout, cuts, details and lists for each panel face.
  • Nesting PDF and Nesting DXF · 1:1: the layout of the sheets of the panels in scope on stock plates. Nesting: arranging parts on a plate with the least waste.
  • Project-wide nesting PDF / DXF: the parts of the whole project are arranged on shared plates.
  • Offcut-pool nesting PDF: the layout is fed first from the parts in the offcut pool; the result row says how many offcuts were used. Adding offcuts to the pool is not an output but an operation that writes to the library; so it is not in the Output centre but in the cladding section, on the Add offcuts to the pool button (see the "Cladding" topic).
  • Casing and door Omega fabrication (PDF / DXF) and Casing and Omega flat patterns (DXF): for trapezoidal faces laid out according to openings, the fabrication list of the casing and Omega parts around doors and windows, a press work order per mark, and flat patterns. If there is no such face, the row is dimmed.

For cladding outputs, a cladding layer that goes into the layout is needed; if there is none, the row says "No nestable cladding layer".

Sheets

  • Sheet set PDF / DXF: all the sheets in the project in order, with the drawing list (cover) at the start and "Page n / N" on each sheet. If the drawing list does not fit in one column, it is split into side-by-side columns, and if that is not enough, into continuation pages. If there are no sheets in the project, the row is dimmed; how sheets are built is in the "Views" and "Sheets" topics. The cover also has its own row in the drawing list and shows the project name in its title block; clicking a sheet number in the list takes the PDF to that sheet. Texts in the PDF are real text: search and copy work in the PDF, and texts stay sharp when zoomed. Coloured elevation and 3D view images are about 300 dpi. The dash pattern of dashed lines grows with the line weight (dash 12 times, gap 3 times the weight; at least a 3 mm dash and a 1.5 mm gap). The floor plan is drawn as if cut 1200 mm above the floor: studs cut at that height show filled with their C sections, truss and roof members entirely above it are drawn with thin dashed lines (a dashed truss end beyond the wall is the eave overhang), and the top track and lintel of a wall are not drawn in plan. The floor plan also shows the room names. When a short wall has no room for its panel name, the name gets a little smaller and may move towards the ends of the wall. The overall dimensions of plans and elevations measure the walls, not the eave overhang; the height dimension in an elevation runs to the ridge. In an elevation, a panel more than half hidden by the walls in front of it is drawn without its name and its doors and windows; a door in an interior wall no longer lands on top of a window in the exterior wall. Dimensions are rounded to one decimal, halves up; equal spacings are written with the same number everywhere.
  • Panel sheets PDF / Panel sheets DXF: the fabrication sheets of the visible panels in scope, in one file; when the option that writes panels with the same mark together is on, identical panels share one page. When a project has marks, a panel without a mark (such as new trusses after a roof rebuild) is grouped with the mark Numbering would give; the mark is not written to the project and the result row warns. User-defined operations and bolt holes come out of the drawing in a balloon on a leader line (Ø13), and their points are dimensioned from the panel edge. Panel sheets have no level marks; their dimensions are from the panel's own bottom edge. So that member numbers and dimensions stay readable, a panel is drawn at 1:50 or larger; while Keep the paper for panel sheets is off, the next paper size is tried when that scale does not fit. When the name and size of a door or window do not fit in the opening on one line, the name is written above and the size below on two lines. The scale bar is at the right end of the view title. In the DXF each panel sheet is a separate layout and the drawing is at real size in model space; when Also write DWG copies of the DXFs is on, a DWG is written next to it.
  • Assembly shop drawings (PDF / DXF): the assembly sheets, part drawings and press work orders of the assemblies built with Create Assembly (see "Assembly: grouping parts"). If there are no assemblies in the project, the row is dimmed.
  • Anchor setting-out plan (PDF / DXF): the foundation anchors and hold-down rods of the wall panels dimensioned to the grid; behind it, the hold-down fabrication. Hold-down: a tension connection that pulls the wall to the foundation. If there are no foundation anchors or hold-downs in the project, the row is dimmed.
  • Placement plan PDF / Placement plan DXF: for each floor, a separate floor plan for each panel type (in order: walls, floors and ceilings, trusses, roof panels and purlins, roof covering, custom panels). Each plan draws and names only the panels of its type. The schedules are on the plan's own sheet: the plan sits at the top left, the schedules fill the free space to its right and below it, and the plan and schedules together are centred on the sheet. The wall plan has the floor's door and window schedule (type code, or for an opening without a type the code written on the plan, name, kind, width, height, quantity; with the total number of doors and windows underneath), the room finish schedule (with the floor, wall, skirting and ceiling layers) and the wall panel list; the truss plan has the truss list; the roof plan has the purlin schedule (code, use, section, length, quantity, total length) and the roof panel list; the roof covering plan has the roof sheet schedule (code, material, width, length, quantity, area) and the trim schedule (code, material, developed width, length, quantity, total length). A schedule that does not fit on the sheet continues on a following page of the same paper size; an empty schedule is not printed. The codes are also written on the plan: purlins A-1, A-2… (the same code as in the member work order), roof sheets S1, S2…, gable trims AK1…, eave trims SK1…, corner caps KK1… (the same codes as in the roof sheet list); where there is no room for the text the code is only in the schedule. Inside the plan each room shows its name, number and area, and a rectangular room also its interior size; a small room shows only its number. The floor's detail sheet follows its plans; the details are cut from the model. A system section from the foundation to the roof runs over two rows of the sheet: floor layers, wall (framing and hatched cladding layers), truss heel, purlin, roof sheet and eave trim, level marks and a dimension from the floor to the top of the wall. There are also gable and window sections. Parts are shown with a code in a red balloon; the codes are the same as in the other outputs: purlins A-1…, roof sheets S1…, trims AK1… / SK1…; panels by name. The cladding layers are written right next to the section with numbered balloons and the material name. For now the program chooses the detail locations (a solid point of the eave wall, the gable trim, the first window); the wall plan gets a section mark with filled arrows for each section, showing the detail number (top) and the number of the detail sheet (bottom). Gable walls (wall panels with a sloped top that sit on top of another wall) are erected together with the trusses, so they are on the truss plan; on a floor without trusses they are on the roof plan. A one-piece sloped wall running from the floor to the ridge stays on the wall plan. For a roof built with Create roof, the purlins and valley beams are on the roof plan, and the covering sheets, gable and eave trims and corner caps are on a separate roof covering plan (seen from above the sheets would hide the purlins). On the covering plan each sheet is drawn by its outline only, without its ribs; the purlins show through in grey and the laps read as double lines. The parts of a roof are included when one of its trusses or gable walls is in the output. For orientation, the type below is drawn in light grey without names: the walls on the truss plan, the trusses on the roof plan. Choose the paper in the Placement plan paper box of the Output Centre: with Automatic the smallest paper (A3, A2, A1, A0) on which the floor's plans fit at 1:100 or larger together with their schedules is used; if you choose a paper (A4 is also available), the plan is drawn at the largest scale that fits it (at most 1:50). You can also choose the scale in the Placement plan scale box (Automatic, 1:50, 1:100, 1:200, 1:500): the plan is drawn at that scale and schedules that do not fit continue on extra pages of the same paper; if the plan does not fit the paper at that scale, the program does not change the scale, the output stops and names the scale that fits. On A4 the title block is short to save space. All plans of a floor share the same paper, frame and scale, so they line up when laid on top of each other; the detail sheet uses the same paper. Dimension texts are at least 2.5 mm high and sit above the dimension line. The panel name is the same as on the panel fabrication sheet. If the panels have been numbered, the plan shows the panel's main mark (for example D-3) instead of its name; the schedule on the plan pairs marks with names. If the numbering is out of date, the Output Centre report warns you. Texts, dimensions and balloons do not overlap: consecutive equal axis spacings are added up in one dimension (for example 25 × 2386 = 59650), narrow dimensions are written in rows, a detail balloon moves to free space, and a section mark has one balloon at one end, outside the plan. A panel name or mark that has no room is left off the plan and named in the report. The wall plan also carries assembly dimensions: outside every exterior wall, a dimension chain of the panel joints (on the outer face of the wall, from building corner to building corner; a single-panel wall has no chain), the distance of the interior walls from the exterior walls (a chain across the walls; each wall is measured at its face looking at the start corner, the last dimension runs to the inner face of the opposite exterior wall), and the Start corner, marked with a red triangle at the lower-left outer corner of the plan; all assembly dimensions are read from that corner. In sections and details, cut frame members (studs, bottom and top tracks, purlins) are drawn filled with their real cross-section, including bend radii and lips. An erection sequence is not produced; the site decides the sequence. In the DXF the same pages as the PDF (plans, list continuations, detail sheet) are separate layouts; plans and sections are at real size in model space. When Also write DWG copies of the DXFs is on, a DWG is written next to it. The first two pages of the file are isometric views of the whole building, each filling its own page: first Frame isometric (cladding, roof sheets and trims hidden), then Clad isometric. Lines are continuous: lines that meet end to end are drawn as one line with round corners. In the DXF such a line is a single polyline, dashed lines use a real linetype (PANELSTUDIO_DASHED), and each layer's colour and lineweight are defined in the file. Balloons are true circles. When there is no room to the right of a section, the material balloons move to its left; when a material's name already includes its thickness, the thickness is not added again.

Lists

  • Net quantities (no waste, packages or prices): what the project contains; the same list as the Net Quantities tab of the Quantities window (see the "Quantities and Material Lists" topic). If there are no quantity data, the row is dimmed.
  • Purchase list (with waste and packages): what to buy; the same list as the Purchasing tab, without prices. If there are no quantity data, the row is dimmed.
  • Panel list: panel, layer, number of profiles, profile length, cladding layer, number of joints.
  • Roof sheet list (count, length, m²): the covering sheets and trims of Create Roof; code, material, width, length, quantity, area and total length. The code depends on the kind: roof sheets S1, S2…, gable trims AK1…, eave trims SK1…, corner caps KK1… (the placement plan writes the same codes).
  • Roof cutting plan: opens when Get cut sheets out of one sheet is ticked in Create Roof. Each sheet to order (code SP1, SP2…): material, width, order length, quantity, the code and length of the parts that come out of it, the length difference of the slanted cut between the two edges, a note if the second part is turned end over end, area and saved area. The total quantity and area match the project quantities.

The lists (cut, screw, net quantities, purchase, panel and roof sheet list, sheet metal flat summary) are each written as one file, in the format chosen in ⚙ Settings › General Settings › General › List files; the initial setting is Excel. With CSV the separator is a semicolon and numbers are written with a dot in every language; you can split them in Excel with "Data › Text to Columns".

3D model

  • 3D model DXF: the project's 3D model in a single DXF file; it can be taken in a project without panels as well. Every element on the screen is a single object in CAD (a multi-face mesh, "polyface mesh"): the panel framing per panel, the cladding per panel and colour if the cladding is open on the screen, and every other element separately. The colours are the colours on the screen; the layer comes from the element type (for example PANEL_KARKAS, PANEL_KAPLAMA, BIRLESIM_ELEMANI, CELIK_PROFIL, CIVATA, KATI_ELEMAN). The visible objects of the DRAW tab are also written as real CAD objects to layers that start with CIZIM_; DXF underlay lines are not written. The unit is mm, the coordinates are the same as in the project; the file opens with a south-west isometric view. Elements on a layer that is off are not written; temporary hide / isolate and the level filter do not change the result.
  • 3D model (IFC 4.3): the project's IFC model; it is the same file as the IFC export on the BIM tab (see the "BIM Tab: Step-by-Step Use" topic).

Analysis model

Analysis model exports the profile model of the wall, truss, floor, ceiling and roof panels, the purlins and the joint elements to a structural analysis program. The program does no calculation and writes no loads: it builds the model, and the engineer does the calculation in their own analysis program. The Model group of the Output Center has two options, both in every plan: Analysis model (SAP2000 .s2k) is the SAP2000 text file, Analysis model (IFC4 structural) is for programs that read the IFC4 structural analysis model, such as RFEM and SOFiSTiK.

The selected panels are exported, or every panel when nothing is selected; the purlins and valley beams of the roofs in the analysis and the joint elements (U, outer corner and inner corner columns) connected to these panels go with them. Free panels are not exported and are listed in the result.

The rules of the model: profiles are brought down to the mid-plane of the panel and their lines pass through the centroid of the section. The ends of studs, nogs, headers, sills, braces, truss webs and braces, floor and roof joists are pinned; wall tracks, truss chords and panel edge profiles are continuous; a steel strap brace carries only tension and compression. Supports are at the foundation anchors and hold-downs of the walls on the lowest storey; if a wall has neither, a pinned support is placed at the base of every stud standing on the bottom track. Walls meeting at a corner, a T or end to end are tied by a short rigid link: the link is fixed to one panel and pinned to the other. When the joint has a joint element, the walls are tied to the column instead of to each other: the column is a single vertical member through the centroid of its body, with a pinned support at its base; the stud of each wall nearest to the column is tied to the column by short links at the same levels. A U column is written in SAP2000 with a cold-formed U section, a corner column with its own L shape as a general section (General); the bend radii of a corner column are not taken into account. The material of the column is the Steel grade in the joint element window; if it is left empty, the framing grade of the first wall tied to the column is used.

An element sitting on its carrier is tied with the same short link: a truss on the top track of a wall, a floor on the walls of the storey below, a roof panel and a purlin on a truss or a wall, an upper-storey wall on a floor or on the wall below it. The link is fixed to the seated element and pinned to the carrier; the real level difference between them is kept. When an upper-storey wall finds a carrier, its base support is removed; when it does not, it is written with supports as on the foundation and listed in the result. A truss, floor, roof panel or purlin that cannot sit on any carrier is listed in the result as well: check its position.

In the SAP2000 file the units are kN and metres, and numbers are written with the Windows decimal separator of this computer (a comma on Turkish Windows); if the computer that will open the file has a different setting, you can choose the separator with the AI assistant. A DEAD load case is written for self weight; define the other loads in the analysis program. The face of every wall, floor and roof panel is written as an area without a section (None): it carries no stiffness, and you can distribute wind and snow loads from these areas to the members with "Uniform to Frame". In the IFC file the units are mm, N and MPa; load areas are not written to IFC.

The result line shows the number of nodes, members, supports and panel links, and the notes you should check: profile ends that do not sit on another profile, panels without anchors or without a bottom track, steel grades not found in the library, unknown sections, joints that could not be linked, joint elements that could not be tied to any wall (and so were not written), upper-storey walls with no carrier found below them and panels that could not sit on any carrier. The diaphragm effect of the cladding (OSB, plasterboard) is not exported.

When you open the file in the analysis program, check the number of nodes and members, the supports and the releases; we recommend checking the first file by comparing the stud force of one panel with a hand calculation.

You can also ask the AI assistant for the same output; the assistant asks for the file path, format and decimal separator, and tells you the notes in the result.

Outputs not in your package

The sheet set, batch panel sheets, anchor layout plan, placement plan and analysis model are in every plan. The other outputs belong to a package module: for example, the machine file and work orders to the Production (roll forming) module, the cladding work order and nesting to the Cladding module, and the material lists and 3D model to the Quantities module. If your licence does not include that module, the output does not appear in the list at all and the ready packages skip it. The details are in the "License and Account" topic.

Fabrication mark options

If there are panels in the project that were given marks with Numbering, a Manufacturing mark box appears on the right:

  • Write panels with the same mark together (mark × quantity) (on by default): the production work order is a single file per mark; the heading has the mark and quantity, and below it the line "4 panels are produced from this work order" with the panel names. The cladding work order is one sheet per mark, with the quantity and panels in the title block. In the cut list, part codes are written with the mark and a Qty column appears at the end. The panels written together must still be exactly the same; a panel that changed after numbering gets its own work order and the result row says "Run Numbering again". If you untick the box, the outputs are per panel.
  • Write the mark before the panel name in the machine file (D-3 Panel-3) (off by default): the machine file still writes each panel separately; only the panel's name changes. Try how the machine prints this name on the profiles on the machine before the first production.

Paper, DWG and folder

  • Paper: the PDF paper (A4 / A3) and Landscape orientation.
  • Keep the paper for panel sheets: if ticked, panel sheets stay on the paper you chose; the paper does not grow for a panel that does not fit, no file is written and the Results list names every panel that does not fit. When off, such a panel moves to the next larger paper.
  • Also write DWG copies of the DXFs: if ticked, a DWG file (2013 format) with the same name is written next to every DXF output. Sheet layouts, real dimensions and title block fields are in the DWG too. In the 3D model DWG, dimensions on a vertical or inclined plane are lines and text (in the DXF they are all real dimensions). The cladding work order and nesting DXFs are in the old DXF format and may not be convertible to DWG; if so, the DXF is still written and the result row says why. In the DXF and DWG of sheets, each element type is on its own layer: panel framing PANEL_KARKAS, cladding PANEL_KAPLAMA, joint element BIRLESIM_ELEMANI, stair MERDIVEN, concrete BETONARME, reinforcement DONATI, bolt CIVATA, steel section CELIK_PROFIL, solid element KATI_ELEMAN; section fill KESIT, section outline KESIT_CIZGI, underlay ALTLIK, elements above the plan cut height UST_ELEMAN, dimensions OLCU, balloons and marks ISARET, texts YAZI. Lines take their colour and lineweight from the layer (ByLayer): when you change a layer's colour in CAD, the drawing changes too. A line drawn in a colour other than its layer's (for example a red warning) keeps its own colour. Section fill is grey, so it no longer shows as a white patch on a dark screen. To see the layer colours on paper, choose a colour plot style table (CTB) in CAD; with a monochrome table the drawing prints black. White balloon backgrounds are not written. Text is the same size as in the PDF.
  • Machine: which machine the machine file and the preflight check are done with; the active machine is at the top of the list. If no machine is defined, this box is not shown.
  • One machine file per level (under the Machine box, off by default): when ticked, the machine file is written level by level; each level is its own file and the level name follows the machine name in the file name (for example ZEMIN-KAT). Levels are in elevation order. Panels without a level and standalone members drawn with Draw Member go to a separate file whose name ends in KATSIZ. If no panel has a level, a single file is written as before. If two levels look the same in a file name, "-2" is added to the second one so the files do not overwrite each other. No file is written for a level without production members; the Result row says so. A delivery record is written for each file.
  • Target folder: by default, the Cikti\year-month-day folder in the project folder (in the Documents folder for an unsaved project). With Change… you can choose another folder.

The next time the window opens, it comes with your last choices: the ticked outputs, paper, orientation, DWG, Open the folder when done, machine and fabrication mark options. The folder you chose with Change… is also remembered (if the folder has been deleted, it goes back to the day's folder); if you never changed the folder, a new date folder is used every day. The choices are in the user settings and are not written into the project.

File names

The program names all outputs in English and in capital letters: first the project, then the document, if needed a distinguishing addition (machine name, mark), and the date last. Parts are separated by an underscore, and words inside a part by a hyphen: YURT-BLOK-A_CUT-LIST_2026-10-25.csv, YURT-BLOK-A_PRODUCTION-WORK-ORDER_D-3_2026-10-25.pdf, YURT-BLOK-A_MACHINE_HAT-1_2026-10-25.ark.

  • The project part is the name of the project file (the project name for an unsaved project); Turkish letters are simplified (Ç→C, Ş→S).
  • The date is in year-month-day format; in the folder, files are ordered by date. The extension stays lower case.
  • The rule does not depend on the output language. For the machine file, only the name of the file follows this rule; the panel names inside do not change.

Title block and real dimensions in DXF and DWG

  • Real length: in sheet DXFs (sheet set), every view sits 1:1 in model space and each sheet is a separate sheet layout (layout). The unit is mm.
  • Title block: the title block on the sheets is a block called PS_ANTET; the values are the attributes of the block. In CAD, double-click the title block (or use ATTEDIT / EATTEDIT) and change fields such as sheet no., revision, sheet name, project, status, prepared by, checked by and date directly. The field names are: PAFTA_NO, REVIZYON, PAFTA_ADI, PROJE, DURUM, HAZIRLAYAN, KONTROL, KAGIT, TARIH, SAYFA; on fabrication sheets also MARKA, ADET, MALZEME, OLCU, AGIRLIK. The revision table is plain drawing outside the block.
  • Real dimensions: the dimensions in the DXF are CAD's own dimension objects (DIMENSION). When you stretch the drawing in the CAD program or move the end of a dimension, the value changes by itself. Dimensions are on the OLCU layer; the style carries the scale of the view (PS_1-20, PS_1-50…), and text and arrows come out at the size in the PDF when the sheet is printed. If the number in the text does not match the drawing (for example the real length of an edge shortened in an isometric view), the text stays fixed.
  • Dimensions you draw with the DIMENSION tab in the 3D model DXF are also real dimensions and stay in their own plane; when stretching a dimension in a vertical plane in CAD, turn the user coordinate system (UCS) to the plane of the dimension.
  • Layer and block names stay the same in every language; only the texts in the drawing are in the output language.

Output language

The language of documents (PDF work orders, sheets, texts inside DXF, human-readable lists) is chosen separately from the interface language: while working with a Turkish interface, you can give an English document to a foreign client. Outputs are written in the output language, not the interface language.

  • ⚙ Settings › General Settings › General › Output language: the default output language of all projects (Turkish or English). It takes effect at once; no restart is needed.
  • PROJECT › Project Info › Project Settings › İmalat Anteti › Output language: this project's language. If Use the general setting is selected, the general setting applies; if Turkish or English is selected, the project always comes out in that language (the choice is saved in the project file).
  • The number and date format also follows the output language: 1.234,5 and 25.10.2026 in a Turkish document, 1,234.5 and 2026-10-25 in an English document. Numbers in CSV files are written with a dot in every language.
  • Everything you write (project, client, panel, material and layer names, notes, the title block template, machine operation names), the suggested file names, DXF layer and block names, and files that programs read such as machine files and IFC do not depend on the language.
  • The result rows and message boxes in the Output centre stay in the interface language.