22
Panel Editing and Splitting
The PANEL › Edit Panel group empties and refills a panel, changes its outer size and local axis, and copies its properties to other panels. The PANEL › Split / Merge Panels group splits a panel into parts or merges parts.
Strip Panel and Fill Panel
- Strip Panel (
PB): leaves only the perimeter profiles (bottom/top track, edge studs, truss perimeter) and the door/window frame (king stud, header, sill) in the panel. Studs, noggings, jack studs, the lattice above the header, braces and manually added profiles are deleted. Doors and windows are not deleted. - Fill Panel (
PD): regenerates the panel from the panel settings (spacings, lattice, brace recipe). Manually added profiles, braces added later and profiles you deleted earlier are removed; doors and windows are kept. Whatever Strip Panel deleted comes back as well. - If a panel is selected the command is applied at once; otherwise it is applied to the panel you click.
Outer Size (↔)
PANEL › Edit Panel › Outer Size moves the left, right, bottom and top edge of a panel by a number.
- Select the panel and press Outer Size (if no panel is selected, click a panel first). The Move Panel Outer Edges window opens.
- For each edge, type the amount to move: a positive value moves the edge outwards, a negative value inwards.
- For an edge that must not move, tick the box such as Keep left edge fixed.
- Each press of Apply repeats the same move once more. Close closes the window.
The last entered amounts and the keep-fixed choices are kept when the window is reopened. Only the moving edge moves; inner corners such as the top of a gable and doors/windows keep their size and place. If a reduction would leave an opening outside the panel, nothing is done and the reason is shown.
Mirror Local Axes (⌖)
The local coordinate system (X, Y, Z arrows) of a panel decides from which end the framing is laid out. Each press of PANEL › Edit Panel › Mirror Local Axes moves the local axis origin to the next corner of the panel outline and turns the X/Y directions towards the inside of the panel; if needed Z is reversed too.
- In upright panels such as walls and trusses, the height direction (Y) never turns downwards; so in practice mirroring only changes the X direction, that is, the end where the first stud starts. The origin is always at the bottom left corner relative to the panel's own axes.
- In horizontal panels such as floors and roofs, all four corners are used.
- The position of the panel in the world does not change. Profiles created by the program are laid out again for the new direction; manually added and frozen profiles stay where they are in the world.
Copy Properties (⧉)
PANEL › Edit Panel › Copy Properties transfers the recipe of one panel to other panels.
- Start the command. If exactly one panel is selected on screen, it becomes the source; otherwise click the source panel whose properties you want to take.
- Click the target panels one by one; each click is applied at once.
- End with Esc or a right click.
Cladding, spacings, section, framing and brace recipe and panel type are copied. The size, place and doors/windows of the target are kept (if the panel type changed, an opening that no longer fits the new outline is removed). The framing of the target is regenerated parametrically; manually added or frozen profiles on the target are deleted.
Changing the size of the selected panel in place
When a single panel is selected, the length of the panel is shown as a blue dimension on its bottom edge and its height on the side edge.
- Click the dimension text you want to change; a box opens in place of the text and the end that will move is marked with an orange dot.
- The local origin (point 0) of the panel is the reference: the edge near the origin stays fixed, the opposite edge moves. While the box is open, Tab switches the fixed edge.
- Type the new value and press Enter. Esc or clicking elsewhere closes it without a change.
- On a panel with a sloped or gable-shaped top edge, the height of each vertical edge is a separate dimension; changing one moves only the top corner of that edge and the slope changes accordingly.
- On a truss, the lengths of the sloped top edges are for information. The top chord also shows a yellow Purlin dimension; click it and type a new spacing, and the truss is regenerated for that spacing.
- The dimensions of door and window openings are shown in green and are changed the same way: position (from the start of the panel to the left edge of the opening), width, height and, for windows, sill height. The framing is rebuilt for the new size. No dimension is shown for non-rectangular openings.
- Doors and windows keep their size and place. If a reduction would leave an opening outside the panel, no change is made and the reason is shown. Every change is undone in one step (Ctrl+Z).
When a single panel is selected, handles also appear at the corners and edge midpoints: a pink circle for a panel corner, a cyan square for an opening corner, a triangle for an edge midpoint. A handle moves only horizontally or vertically in the panel; the possible directions are shown with an arrow. Drag and release, or click and move with the cursor; you can also type the distance and press Enter, Esc cancels.
Split Long Walls
Splits a wall that is longer than can be transported or produced in one piece on the machine into equal panels. The program proposes the split; if you do not confirm, nothing changes.
- Limit: in the Splitting long walls into panels section of the Panels and production page in the ⚙ Settings › Program › General window, enter Longest exterior wall panel (mm) and Longest interior wall panel (mm) (0 = no limit for that wall type). The longest profile length of the active machine is also a limit; the smaller of the two applies. The setting applies to all projects.
- When it is asked: when you draw a wall longer than the limit with Draw Panel (single) or Draw Panel Chain, or with PANEL › Split / Merge Panels › Split Long Walls (selected walls; if nothing is selected, all walls in the project).
- Confirmation: the joints are shown in the model with preview lines; the window lists the length, limit and parts of each wall (e.g. "Panel-3: 14200 mm > 6000 mm → 3 panels (4733 + 4734 + 4733 mm)"). Yes splits, No leaves it as it is.
- Joint position: the wall is split into the smallest number of equal parts. If a joint falls closer to a door/window, or to another wall that ends against this wall (T junction), than Minimum distance from a joint to a door/window (mm) (default 300 mm), it is moved; if that is not possible, one more part is added. The shortest part is 600 mm.
- On a trapezoid facade: if RIB in the status bar is on and the outside cladding is a vertical trapezoid sheet, the parts are separated by rib; if the wall does not fit, the confirmation window says by how many mm it would have to be shortened to fit.
- Parts: each part is a copy of the source panel and its framing is regenerated; at a joint each panel gets its own end stud, so the two studs sit back to back. Parts take the next panel numbers (Panel-25, Panel-26…). Information that belongs to the start or end of the panel (operations on the end stud, edge detail at the end) stays on the part that carries that end.
- Not split: walls with fixed framing (imported or frozen), walls with manually added profiles, and walls with a custom operation tied to selected profiles; the window gives the reason. Split those with Split at Profile.
The split is undone in one step.
Split at Profile
Splits a panel at the stud you choose.
- Select the panel and click the stud where you want to split (or Alt + click). To split at several places, select more studs with Ctrl; each becomes a joint.
- Press PANEL › Split / Merge Panels › Split at Profile, or right-click the stud and choose Split panel at this profile.
- The joint is the line of the stud. Example: if an 18 m wall with 600 mm spacing is split at the stud at 6000, two panels of 6000 + 12000 mm result. Only a vertical profile can be used: a wall stud, a truss post, or a profile in the joist direction in a roof/floor.
- Parametric panel: the framing of the parts is regenerated from the rules; the rules of long wall splitting apply (shortest part 600 mm, minimum distance to a door/window). If there is a manually added profile or an operation tied to selected profiles, it is not split; first freeze it with Properties › Framing › Freeze framing.
- Frozen or imported panel: profiles stay as they are; the tracks and noggings that cross the joint are cut at the joint. If the other part has no stud at that end, a reversed copy of the selected stud is added. The shortest part is 100 mm.
- A joint that cuts through an opening is not made. Parts take the next panel numbers; the split is undone in one step. If the panel is shown alone with Isolate, the parts stay visible too.
Split at Ridge
Select one or more trusses and press PANEL › Split / Merge Panels › Split at Ridge (or right-click a truss and choose Split truss at ridge). Each truss is split at its ridge (the highest point; the middle of the top on a flat top) into two half trusses; each half gets its own end post at the ridge.
- A truss whose peak is at one end (mono-pitch truss, flat beam), a truss where a half would be shorter than 600 mm, a truss with manually added profiles and a frozen truss without a post at the ridge are not split; those that are not split are listed with the reasons.
- The whole selection is undone in one step. If you rebuild the roof with Create roof, the trusses are built whole again.
Split Panel, Split at Crossing, Merge Panels
- Split Panel: splits a panel that was merged too much during import into its parts. The split is made where both the bottom and top tracks have a gap (a door only cuts the bottom track, so it is not split at a door). The framing of the parts is frozen.
- Split at Crossing: first select the cutting panel, then press the button. The parametric panel that the cutting panel physically cuts is split into two independent parts; the parts extend to the center line of the cutting panel.
- Merge Panels: merges panel parts that were split because of a door into a single panel. Select the parts with Ctrl + click; they must be on the same wall line. The merged panel takes the next number, its profiles are kept (the framing becomes frozen) and doors/windows are detected again.