Guide topics

28

Cladding Consumables

A consumable is an auxiliary material used together with cladding: board and sheet screws, seam screws, joint tape, sealant, accessories and joint profiles. The program does not guess the product name or the calculation rule; you define which product is used on which cladding and at which spacing. A consumable that is not defined never enters any list on its own.

Where consumables are defined

Both are in the ⚙ Settings › Company libraries › Materials & Sections window and apply to all projects:

  • Cladding materials page: the consumable product itself (its name, manufacturer, product code, type, screw diameter and length, stock length).
  • Cladding consumables page: the rule that links the product to a cladding material.

Step by step: defining a consumable rule

  1. On the Cladding materials page, add the product. For a screw, set Material type to Fastener and fill in the Screw diameter (mm) and Screw length (mm) columns (3.5 × 25, 3.5 × 35 …). For a joint profile, set the type to Accessory, choose its unit as pcs or lin. m and enter the stock length in the Length column of the Stock sizes tab.
  2. On the Cladding consumables page, click Add consumable rule.
  3. In the Used with cladding column choose the cladding material (for example BETOPAN 10mm), and in the Consumable product column choose the product.
  4. Enter the Usage, Face, spacing, edge distance, Quantity per point and Waste (%) values.
  5. Click Save changes.

Rule columns:

  • Usage: the job of the consumable (see "Usage types" below).
  • Face: Both faces, Outer face only or Inner face only. Even if the same board is on both faces, one consumable can be used on only one face.
  • Joint direction (joint profile): only for a joint profile; vertical and horizontal, vertical only or horizontal only joints.
  • Spacing · vertical member (mm) and Spacing · horizontal member (mm): the screw spacing. If horizontal is empty, it is the same as vertical.
  • Distance to board edge (mm): the smallest distance of the screw from the board edge.
  • Screwed members: for board screws, All members (studs, tracks and rails) or Horizontal members only (bottom/top tracks and rails; no screws on the studs).
  • Fixed spacing: when ticked, the screws are laid on one grid with fixed steps starting at the board edge (see "Board screws" below).
  • Screw cap (none on tracks): only on a Sheet → frame fixing (screw) row; None or a cap product. The cap is placed over the screws of this row; screws on the bottom and top tracks have no cap, one cap is counted for every other screw. The cap is a separate item in quantities, shipping and purchase lists. The list shows the accessories and fasteners of Cladding materials; define the cap product there with type Accessory, counted in pieces, and the cap colour. The screw itself or a product counted in m² is not saved as a cap.
  • Steel penetration (mm): the length the screw must project after passing through the profile sheet; it is used when choosing the screw length.
  • Quantity per point and Waste (%).

A new rule comes with spacing 500, edge distance 15 and steel penetration 7 mm; correct the values for your own product.

Usage types

  • Sheet → frame fixing (screw): the screw that fixes the board or the trapezoidal sheet to the frame.
  • Sheet lap / seam fixing: the seam screw placed along the joints (laps) of trapezoidal sheets at the spacing in the rule.
  • Joint tape: as long as the joints between boards (m).
  • Sealant and Accessory: as long as the panel perimeter (m).
  • Joint profile (omega, H …): profile lengths calculated from the real joints.

Board screws (flat boards)

For flat boards such as Betopan and plasterboard, a rule whose usage is Sheet → frame fixing (screw) is applied as follows:

  • Screws are placed on the flange of the stud, track and rail that pass under each piece of board; no screw is put on a diagonal profile.
  • Screws at the ends are at the edge distance and those between are spread evenly so that they do not exceed the spacing. Two close points where a stud and a rail cross count as one screw.
  • With Fixed spacing ticked the screws do not divide the member length evenly: the first screw is at the edge distance of the board, the next ones at spacing steps counted from the board edge, and the last one at the edge distance of the far edge. Where the board edge sits on the panel edge the spacing steps are counted from the panel corner, and the end screws stay at the edge distance (1200 mm board, 400 spacing, 25 edge distance: 25, 400, 800, 1175). At the joint between two boards and at the edge of a door or window opening the steps are counted from the edge distance. All rows of the same board line up; the last gap may be short, and no gap exceeds the spacing in the rule. A rail made of pieces between the studs counts as one continuous row.
  • With Screwed members set to Horizontal members only, screws go only on the bottom/top tracks and the rails.
  • Example values: plasterboard 250 mm spacing / 15 mm edge, all members; Betopan 400 × 400 mm spacing / 20 mm edge, horizontal members only, fixed spacing and a cap product in the Screw cap column.
  • The screw marks in 3D are visible with cladding on; each screw is visible only from outside its own face. The screw head is drawn from the Screw head choice of the product: Pan, Hex with washer (trapezoidal sheet screw) or Countersunk (flush with the surface). For a product whose material type is not Fastener the screw head is always None and its cell in the table is dimmed and locked; a screw without a choice is drawn as pan. A capped screw shows a flat dome in the colour of the cap product instead of its head.
  • The cladding manufacturing drawing (PDF) and the DXF also draw the screw symbol by head type: a circle with a star slot for pan, two concentric circles with the slot for countersunk, a washer circle with a hexagon for hex. A capped screw is a filled cap circle with a small dot in the middle; in the DXF it is on its own SARF_KAPAK layer. The screw information of the face page also gives the number of caps.

Screw length

If the diameter and length are filled in for the screw products, the program calculates the screw length needed for each layer: the layers from the screwed layer to the frame + the profile sheet + the Steel penetration. Among the screws with the same diameter as the screw in the rule, the shortest one that meets this length is chosen.

  • Example, double plasterboard: layer near the frame 12.5 + 1 + 7 = 20.5 mm → 3.5 × 25; outer layer 25 + 1 + 7 = 33 mm → 3.5 × 35. Both layers are screwed at the same spacing.
  • If there is no screw long enough, the longest is chosen and Cladding Validation warns (see the "Production Readiness" topic).
  • On trapezoid a screw into the valley can be as short as the rib height. For the pattern of trapezoid screws see the "Trapezoid screws" section of the "Cladding" topic.

Seam screws

A seam screw joins the laps of several trapezoidal sheets together. It is defined with a rule whose usage is Sheet lap / seam fixing.

  • A seam screw is not mandatory: if you do not define it, Cladding Validation does not warn.
  • If you define it, it enters the consumable calculation, the cladding work order and the 3D view.
  • The Sheet → frame fixing (screw) rule that fixes the trapezoid to the frame is mandatory; if this rule is missing on trapezoidal cladding, Cladding Validation gives an error.

Joint profile rule

If you want the same board to always get the same OMEGA or PVC H joint profile in all projects, define it in the library as a rule: with usage Joint profile (omega, H …), and the Face and Joint direction columns.

  • Lengths are calculated from the joints in the real board layout: doors, windows and the opposite joint split a joint, and each piece is a separate length. Short pieces are fitted into the same stock length to find how many lengths are needed; if no stock length is entered, 3000 mm is used. The saw kerf is taken from the product's own card.
  • For a profile that changes from project to project or from board to board, choose on the board itself instead of a library rule (see the "Joint profile" section of the "Cladding" topic). A profile chosen on the board takes precedence over the library rule; no profile is placed on a board where None is chosen.
  • If the library has no rule and no profile is chosen on the board either, no joint line and quantity appear in the cladding work order.

Where consumables appear

  • Screw marks in 3D, the cladding work order (PDF and DXF) and the production outputs are fed from the same rule and the real board layout (see the "Output Centre" topic).
  • The project total is in QUANTITIES › Lists › Material List (see the "Quantities and Material Lists" topic).