Guide topics

40

General Settings

⚙ Settings › Program › General Settings collects the program preferences on this computer: language, unit, display, grid, navigation, drafting aids, keyboard, command line, ribbon icons and panel splitting limits. Every setting here applies to all projects on this computer. Project settings (title block, text styles) are in PROJECT › Project Info › Project Settings, and machine settings are in PRODUCTION & OUTPUT › Production readiness › Machine Settings.

Using the window

  • The pages are listed on the left: General, Display, Grid and work plane, Mouse and navigation, Drafting and snapping, Keyboard, Command line, Ribbon icons, Panels and production.
  • When you type a word in the Search settings box above the list (for example "weight", "ERP", "icon"), only the pages that contain that word remain. Upper and lower case and Turkish letter differences are ignored.
  • At the top right, the name of the page and "This computer · applies to all projects" are written. The window opens on the page you opened last, as long as the program stays open.
  • Apply applies and saves the settings; the window stays open. OK applies and closes. Cancel or Esc drops changes that were not applied.
  • Theme, colour and icon changes are visible as soon as you choose them but are saved only with Apply or OK; Cancel returns the look to the last applied state.
  • If a box has a wrong number, no setting is applied; that page opens and the wrong box is selected.

General: language, output language, unit

  • Application language: Türkçe or English. The choice takes effect when the program is restarted. The language changes only the texts on screen; measure entry, the decimal separator and file formats stay the same. A few texts that are not translated yet may appear in Turkish.
  • Output language: PDF work orders, sheets, texts inside DXF and lists are produced in this language; number and date formats follow it (Turkish 1.234,5 and 25.10.2026, English 1,234.5 and 2026-10-25). It is independent of the interface language and takes effect at once with Apply. To give a single project another language, use PROJECT › Project Info › Project Settings › İmalat Anteti › Output language; the language chosen there overrides this setting.
  • List files: quantity, purchase, cut, panel and screw lists, the price list, the shipping list and the sheet metal flat summary are saved as Excel (.xlsx) (initial setting) or CSV (.csv). Save windows offer this format first and the other one can still be chosen; the Output Centre writes the lists in this format as one file each. Machine and ERP files are not affected.
  • Units › Length: Millimetre (mm), Centimetre (cm), Metre (m), Inch (in), Foot (ft) or Feet-inches, fractional (ft-in). Lengths are shown on screen in this unit and typed from the keyboard in this unit.
  • Precision: the largest number of decimals shown on screen for decimal units (0–6; trailing zeros are not written), and the smallest fraction for feet-inches (for example 1/16"). When you change the unit, the precision moves to the recommended value of that unit; you can change it afterwards.

Display: screen and theme

  • Interface › Theme: CAD or Modern; Interface › Mode: Dark or Light.
  • Drawing area theme: Technical (dark), Paper (light) or Presentation. The theme sets the background, the colour of the horizontal plane and the line colour together; on the light theme near-white lines are drawn dark. Layer colours do not change.
  • Background: Solid colour (Dark, Light, Green, Blue, Custom...) or Ground to sky gradient (Default, Sky, Sunset, Dark studio, or your own colours with the Top (sky) and Bottom (ground) buttons). On a new installation the background is a gradient: dark grey at the top, light grey at the bottom. If you change it, the program remembers your choice; the Default button returns to these colours.
  • Selection colours: the colour of panel, profile and cladding selection; changed with Colour palette....
  • Line weights: Show line weights (while off, all lines are 1 pixel, the classic CAD look), Edge smoothing (MSAA) and Weight scale (0.3–3; Thin, Normal, Bold). The LWT button in the status bar turns the same setting on and off.
  • 2D view: in plan and elevation views, draw drawings, dimensions and axes on top of solids.
  • Bolt display: Exact (head, washer and nut) or Fast (shank only). In a model with thousands of bolts, Fast makes orbiting smoother; quantities and export do not change.
  • 3D detail: Fast, Balanced or Full; chooses when distant detail is simplified (see the 3D detail topic above).
  • Dimension text: if ticked, dimension text does not grow when you zoom in; it always keeps the same size on screen.

Grid, navigation and drafting aids

  • Grid and work plane: Show grid, Step (m), Grid line weight (pt); the colour of the horizontal plane (Dark, Light, Grey, Red, Custom...) and Opacity (between 0 and 1).
  • Mouse and navigation: Zoom sensitivity (a lower value zooms more slowly; at 0.4 one wheel notch zooms 1.4 times), Pan sensitivity and Zoom-out limit.
  • Drafting and snapping: Crosshair size (pixels; 0 = full screen), Pick box size (pixels; 0 = hidden), Snap marker diameter (in model size; enlarge it in a large project).
  • Drawing tracking: Perpendicular angle and Axis tracking angle (degrees; 0 = off, 45 at most). While drawing a panel, if the line is closer to perpendicular than this angle to the face of another panel, the point lands on the perpendicular foot; a line within this angle of the X or Y axis from the first point lands on the axis.
  • Snap types (end, middle, intersection…) are on the OSNAP button in the status bar (see "Snapping and Drawing Aids").

Keyboard, command line and ribbon icons

  • Keyboard: in the shortcut table (Group, Command, Shortcut, Default) select a command, press Assign shortcut... and then press the key combination you want. The same shortcut cannot be assigned to two commands. Remove assignment, Reset selected and Reset all are here too. In the Arrow key nudge section the steps for Arrow key, Alt + arrow and Ctrl + arrow are written. Details are in the topic "Mouse and Keyboard".
  • Command line: Show the command line (the current shortcut is written beside it; the default is Ctrl+9) and the alias table (Alias, Command, Ribbon name; Add alias, Remove selected, Restore defaults). Details are in the topic "Command Line and Command Search".
  • Ribbon icons: choose a button from the list and give your own image with Choose icon... (PNG is recommended: transparent background, 64×64 or larger). Restore default returns that button, Reset all returns all of them to the original look.

Panels and production: panel splitting

  • Splitting long walls into panels: Longest exterior wall panel (mm), Longest interior wall panel (mm) and Minimum distance from a joint to a door/window (mm). If a wall is longer than the length here or than the longest profile length of the active machine, the program offers to split it; if you decline, the panel stays as it is. If you write 0, there is no transport or erection limit for that wall type (the machine limit still applies). The minimum distance is also used when splitting at a profile or at the ridge (see "Panel Editing and Splitting").
  • Trapezoidal ribs (RIB): while RIB is on in the status bar, the length and joints of a panel with trapezoidal cladding are chosen according to the ribs.
  • Files written with the production file: the machine file (.ark) is always written. You choose the extra files written beside it (for example ERP exchange (.erp.csv)) by ticking them; they are written to the same folder with the same name (see "Output Centre").
  • Save PDFs as PDF/A (archive): all PDF outputs (sheets, lists, work orders, quotes) are written as PDF/A-3b for long-term archiving and official delivery. The connection detail sheet stays a plain PDF. You can see this in your PDF viewer's Document Properties window: the subject and keywords say PDF/A-3b. In every PDF the title is the file name and the creating program is AXION.

Text styles

Text styles belong to the project and are stored with the project file: PROJECT › Project Info › Project Settings › Text styles (see "Project Settings, Levels and Work Plane").

Start-up screen

While the program starts, the AXION BIM image is shown in the middle and disappears when the main window is ready. If you do not want it, untick Show the start-up screen on the General page; the change takes effect at the next start.

Settings and library backup

There are two buttons in the Settings and library backup section at the bottom of the General page. Both are file jobs, so they work at once without waiting for Apply.

  • Back up…: writes machine and die definitions, section and material libraries, quantity cards, edge detail rules, the component and detail library and the program settings to a single .psbackup file. Projects (.axi) are not included in this file; keep them separately.
  • Restore from backup…: first checks the file (if it is damaged or is another kind of file, it does not restore); it shows the date of the backup, the computer it was made on and the number of files and asks for confirmation. When you confirm, a backup of today's state is made first (the folder is written in the message), then the files in the backup are written to their places; files that are not in the backup are not touched. The program must be reopened for the new settings to apply; if you answer Yes to "Restart the program now?", the program closes and reopens. Until it reopens, setting changes are not saved.

The AI assistant section on the same page is described in the topic "AI Assistant".

Error reports

When an unexpected error occurs, the program sends AXION a technical summary of it, so that we can see and fix the error without you having to report it. Permission is requested during installation and the box is ticked by default.

  • What is sent: error type and message, where in the program it happened, the last command, program and Windows version, the time of the error. The report is linked to your account.
  • What is not sent: project content, drawings, screenshots, log files, file and folder names.
  • Turning it on or off: ⚙ Settings › General Settings › General › Error reports › Send error reports. Turning it off also deletes reports waiting to be sent.
  • Without an internet connection, reports wait on the computer (up to 20 reports, 30 days) and are sent at the next start. They are kept on the server for 6 months and then deleted automatically.